Pachymetry before or after applanation tonometry: does it matter?

نویسندگان

  • S Pourjavan
  • C Deghislage
  • L Van Malderen
  • T Zeyen
چکیده

We examined prospectively 60 healthy volunteers to evaluate if the accuracy of central corneal thickness (CCT) measurement is influenced by Goldmann applanation tonometry (GAT) and vice versa. The sequence of the examinations in the right eye was CCT--GAT--CCT, in the left eye GAT--CCT--GAT and the measurements were done consecutively. Two tonometry and five pachymetry measurements were averaged each time. Pearson correlation coefficients and Bland-Altman plots were used to assess the correlation between the measurements. In the right eye the mean CCT measurement before and after GAT was 565.22 +/- 32.99 micro and 566.04 +/- 33.50 micro (p = 0.34, r = 0.98) respectively. In the left eye the mean GAT before and after pachymetry was 19.38 +/- 4.71 mmHg and 19.16 +/- 4.32 mmHg (p = 0.43, r = 0.86) respectively. The study suggests that the sequence of the two examinations doesn't matter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pressure phosphene tonometry versus Goldmann applanation tonometry for measuring intraocular pressure before and after LASIK.

PURPOSE To compare pressure phosphene tonometry with Goldmann applanation tonometry for measuring intraocular pressure (IOP) before and after LASIK. METHODS Forty-three (18 men and 25 women) consecutive healthy patients underwent complete pre- and postoperative LASIK ophthalmologic assessments including manifest and cycloplegic refraction, keratometry, and central corneal thickness. Three rep...

متن کامل

Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery

BACKGROUND The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer corneal compensated IOP (ORA IOPcc) and Pentacam corrected IOP. METHODS A prospective comparative clinica...

متن کامل

Intraocular pressure measurements after corneal collagen crosslinking with riboflavin and ultraviolet A in eyes with keratoconus.

PURPOSE To determine the possible effect of corneal collagen crosslinking (CXL) with riboflavin and ultraviolet A (UVA) on intraocular pressure (IOP) measurements by Goldmann applanation tonometry (GAT). SETTING Institute of Vision and Optics, Faculty of Medicine, University of Crete, Heraklion, Crete, Greece. DESIGN Prospective case series. METHODS This noncomparative study measured IOP ...

متن کامل

Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry

INTRODUCTION Intraocular pressure (IOP) determination using dynamic contour tonometry (DCT) has been considered to be independent of central corneal thickness (CCT), while Goldmann applanation tonometry (GAT) is known to be influenced by various corneal properties. In this study, IOP was measured before and 1 day after cataract surgery using GAT and DCT to investigate the possible effects of co...

متن کامل

Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings.

BACKGROUND Several authors reported incorrect high intraocular pressure (IOP) values in eyes with a thick cornea using applanation tonometry. This hypothesis was checked by comparing applanation tonometry with direct intracameral manometry. METHODS 73 patients, scheduled for intraocular surgery, were enrolled. Immediately before surgery, the following were registered: (i) central corneal thic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bulletin de la Societe belge d'ophtalmologie

دوره 296  شماره 

صفحات  -

تاریخ انتشار 2005