A One ppm NDIR Methane Gas Sensor with Single Frequency Filter Denoising Algorithm

نویسندگان

  • Zipeng Zhu
  • Yuhui Xu
  • Binqing Jiang
چکیده

A non-dispersive infrared (NDIR) methane gas sensor prototype has achieved a minimum detection limit of 1 parts per million by volume (ppm). The central idea of the design of the sensor is to decrease the detection limit by increasing the signal to noise ratio (SNR) of the system. In order to decrease the noise level, a single frequency filter algorithm based on fast Fourier transform (FFT) is adopted for signal processing. Through simulation and experiment, it is found that the full width at half maximum (FWHM) of the filter narrows with the extension of sampling period and the increase of lamp modulation frequency, and at some optimum sampling period and modulation frequency, the filtered signal maintains a noise to signal ratio of below 1/10,000. The sensor prototype provides the key techniques for a hand-held methane detector that has a low cost and a high resolution. Such a detector may facilitate the detection of leakage of city natural gas pipelines buried underground, the monitoring of landfill gas, the monitoring of air quality and so on.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Cost Optical Electronic Nose for Biomedical Applications

Here we report on the development of a Non-Dispersive Infrared Sensor (NDIR) optical electronic nose, which we intend to target towards healthcare applications. Our innovative electronic nose uses an array of four different tuneable infra-red detectors to analyse the gas/volatile content of a sample under test. The instrument has the facility to scan a range of wavelengths from 3.1 μm and 10.5 ...

متن کامل

Use of a Dynamic Enclosure Approach to Test the Accuracy of the NDIR Sensor: Evaluation Based on the CO2 Equilibration Pattern

As part of a quality assurance (QA) study for sensor systems, an enclosureapproach is applied to assess the accuracy of non-dispersive infrared (NDIR)-based CO₂sensors. To examine the performance of the sensor system, an enclosure chambercontaining six sensor units of the two model types (B-530 and H-500) was equilibratedwith calibrated CO₂ standards at varying concentration levels. Initially, ...

متن کامل

On-Line Measurement of Dissolved Methane Concentration During Methane Fermentation in a Loop Bioreactor

A dissolved methane sensor based on silicone tube was designed, constructed and optimized.The silicone tube diameter, silicone tube length and helium flow rate (as the carrier gas(were considered as process parameters to be optimized.A continuous stream of helium (50 mL/min) was directed through the tubing, sweeping out the...

متن کامل

High Bandwidth Sensor Module for Mobile Robot Applications-Wind Tunnel Characterization

We have developed a sensor module containing high-bandwidth VOC and gas sensors (including novel acoustic, custom MOX and low-cost NDIR) to evaluate the concentration of gases in a hazardous environment. We report upon the initial characterization of two MOX gas sensors (1 mm × 1 mm) with coatings of Pd/Pt doped SnO2 and pure WO3 inside a wind tunnel to plumes of acetone and ethanol (<10 ppm). ...

متن کامل

A New Shearlet Framework for Image Denoising

Traditional noise removal methods like Non-Local Means create spurious boundaries inside regular zones. Visushrink removes too many coefficients and yields recovered images that are overly smoothed. In Bayesshrink method, sharp features are preserved. However, PSNR (Peak Signal-to-Noise Ratio) is considerably low. BLS-GSM generates some discontinuous information during the course of denoising a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012