Endoleaks after endovascular aneurysm repair lead to nonuniform intra-aneurysm sac pressure.
نویسندگان
چکیده
OBJECTIVE This was a study of intra-aneurysm sac pressures in patients who presented with endoleaks after endovascular repair (EVAR) of abdominal aortic aneurysms (AAA). METHODS Twenty-five patients (18 men, 7 women) with endoleaks, age (IQR 68 to 80), underwent 31 direct intra-aneurysm sac pressure measurements, DISP at 16 months after EVAR (IQR, 14 to 26 months). Diameter of AAA was 59 mm (IQR, 52 to 67 mm). Six patients underwent DISP twice. Tip-pressure sensors were used through direct translumbar puncture of the AAA except in three patients (transabdominal puncture in 2; endoluminal in 1). Mean pressure index (MPI) was calculated between simultaneously registered intra-aneurysm sac and systemic pressures. Values presented are medians with interquartile range (IQR). RESULTS Type I endoleaks (n = 1) showed MPI of 93% in the nidus and 62% in the thrombus. Type II endoleaks were associated with lower MPIs in the thrombus (35%; IQR 24% to 38%) when AAAs shrank (n = 4) compared with when the AAAs remained unchanged (n = 11; MPI, 78%; IQR, 47% to 85%) or expanded (n = 6; MPI, 74%; IQR, 58% to 87%; P = .019). The nidus of type II endoleaks (MPI, 79%; IQR, 70% to 90%) had higher pressure than the thrombus (45%, IQR, 34% to 85%; P = .047; n = 7). Successful embolization of type II endoleaks led to AAA shrinkage (n = 3; MPI reduction, 13% to 31%) or diameter stability (n = 3; unchanged MPIs, 37% to 44%). Type III endoleaks (n = 3) had MPIs in the thrombus of 33% to 70%. CONCLUSIONS Endoleaks after EVAR pressurize the AAA sac nonuniformly, with higher, near-systemic, pressure in the endoleak nidus compared with the thrombus. Nevertheless, type II endoleaks in shrinking AAAs have lower intra-sac pressure than expanding or stable aneurysms, and successful endoleak embolization reduces pressure.
منابع مشابه
Surgical Experience of Persistent Type 2 Endoleaks with Aneurysmal Sac Enlargement after Endovascular Aneurysm Repair
Herein, we present a case of a successful treatment of persistent type 2 endoleaks associated with aneurysmal sac enlargement after endovascular aneurysm repair in an elderly patient. We confirmed the diagnosis by abdominal computed tomography and selective angiography revealing an 11.0-cm aneurysm sac with type 2 endoleaks. An attempt for the endovascular embolization of collateral arteries wa...
متن کاملPercutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm
OBJECTIVE The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair. MATERIALS AND METHODS Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate ...
متن کاملSecondary interventions following endovascular repair of abdominal aortic aneurysm.
Endovascular aneurysm repair (EVAR) of the abdominal aortic aneurysms is an attractive alternative to open surgery with significantly improved perioperative outcomes. However, EVAR is accompanied by a higher rate of graft-related complications and secondary interventions. Therefore, life-long surveillance and management of secondary treatment is essential for successful EVAR. Endoleaks are one ...
متن کاملA new injectable radiopaque chitosan-based sclerosing embolizing hydrogel for endovascular therapies.
Endovascular repair of abdominal aortic aneurysms with a stent graft is limited by the persistence or recurrence of endoleaks. These are believed to be related to the recanalization of the aneurismal sac by endothelialized neochannels, which could lead to late type I and II endoleaks. Embolization has been proposed to treat or prevent endoleaks, but presently commercialized embolizing materials...
متن کاملDuplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study*
OBJECTIVE To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. MATERIALS AND METHODS This was a prospective study involving 30 patients who had undergone endovascular repair of infrar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of vascular surgery
دوره 46 2 شماره
صفحات -
تاریخ انتشار 2007