Motion correction in post-injection dynamic cardiac T1-mapping: preliminary results

نویسندگان

  • Anne Menini
  • Pauline Ferry
  • Marine Beaumont
  • Jeffrey A. Stainsby
  • Glenn S. Slavin
  • Laurent Bonnemains
  • Jacques Felblinger
  • Freddy Odille
چکیده

Motion correction in post-injection dynamic cardiac T1-mapping: preliminary results Anne Menini, Pauline Ferry, Marine Beaumont, Jeffrey A. Stainsby, Glenn S. Slavin, Laurent Bonnemains, Jacques Felblinger, and Freddy Odille IADI, Université de Lorraine, Nancy, France, Global Research, GE, Garching b. München, Germany, U947, INSERM, Nancy, France, CIC, INSERM, Nancy, France, CHU Nancy, Nancy, France, Healthcare, GE, Toronto, ON, Canada, Healthcare, GE, Bethesda, MD, United States

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid cardiac T1 mapping within two heartbeats

Introduction: T1-mapping offers a mean to quantitatively assess structural changes in the myocardium. Pre-contrast T1 mapping may assess areas at risk while post-contrast delayed-enhancement T1 mapping may assess myocardial infarction [1-3]. Multi-point T1 mapping approaches, such as Modified Look-Locker inversion recovery (MOLLI) [4], have been shown to detect changes in myocardial T1 in both ...

متن کامل

Myocardial T1 and T2 mappings with automatic motion correction at 3 Tesla MR: comparison of T1 and T2 measurements by breathhold, free-breathing and cardiac cycle

Methods Myocardial T1 and T2 mapping at 3 Tesla MR was obtained from 24 healthy volunteers (16 males and 8 females, mean age, 31±4 years). Shortened modified looklocker inversion recovery was used for T1 mapping and T2-prepared single-shot steady-state free precession was utilized for T2 mapping. Automatic motion correction was done by an elastic registration algorithm based on estimating motio...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدل‌سازی منحنی چند جمله ای

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013