Beam-induced damage on diffractive hard X-ray optics
نویسندگان
چکیده
The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both ambient and inert atmospheres. Diffraction gratings fabricated by three different techniques are considered: electroplated Au gratings both with and without the polymer mold, and Ir-coated Si gratings. The beam-induced damage is monitored by X-ray diffraction and evaluated using scanning electron microscopy.
منابع مشابه
Damage investigation on tungsten and diamond diffractive optics at a hard x-ray free-electron laser.
Focusing hard x-ray free-electron laser radiation with extremely high fluence sets stringent demands on the x-ray optics. Any material placed in an intense x-ray beam is at risk of being damaged. Therefore, it is crucial to find the damage thresholds for focusing optics. In this paper we report experimental results of exposing tungsten and diamond diffractive optics to a prefocused 8.2 keV free...
متن کاملThermal stability of tungsten zone plates for focusing hard x-ray free-electron laser radiation
Diffractive Fresnel zone plates made of tungsten show great promise for focusing hard x-ray free-electron laser (XFEL) radiation to very small spot sizes. However, they have to withstand the high-intensity pulses of the beam without being damaged. This might be problematic since each XFEL pulse will create a significant temperature increase in the zone plate nanostructures and it is therefore c...
متن کاملPtychographic characterization of the wavefield in the focus of reflective hard X-ray optics.
A technique for quantitatively characterizing the complex-valued focal wavefield of arbitrary optics is described and applied to reconstructing the coherent focused beam produced by a reflective/diffractive hard X-ray mirror. This phase-retrieval method, based on ptychography, represents an important advance in X-ray optics characterization because the information obtained and potential resolut...
متن کاملElectromagnetic-field distribution measurements in the soft x-ray range: full characterization of a soft x-ray laser beam.
We report direct measurement of the electromagnetic-field spatial distribution in a neonlike Ar capillary discharge-driven soft x-ray laser beam. The wave front was fully characterized in a single shot using a Shack-Hartmann diffractive optics sensor. The wave front was observed to be dependent on the discharge pressure and capillary length, as a result of beam refraction variations in the capi...
متن کاملZone Plates for Hard X-Ray Free-Electron Lasers
Hard x-ray free-electron lasers are novel sources of coherent x-rays with unprecedented brightness and very short pulses. The radiation from these sources enables a wide range of new experiments that were not possible with previous x-ray sources. Many of these experiments require the possibility to focus the intense x-ray beam onto small samples. This Thesis investigates the possibility to use ...
متن کامل