Performance of the NPP-VIIRS and aqua-MODIS Aerosol Optical Depth Products over the Yangtze River Basin

نویسندگان

  • Lijie He
  • Lunche Wang
  • Aiwen Lin
  • Ming Zhang
  • Muhammad Bilal
  • Jing Wei
چکیده

The visible infrared imaging radiometer suite (VIIRS) environmental data record aerosol product (VIIRS_EDR) and the Aqua-moderate resolution imaging spectroradiometer (MYD04) collection 6 (C6) aerosol optical depth (AOD) products are validated against the Cimel sun–photometer (CE318) AOD measurements during different air quality conditions over the Yangtze river basin (YRB) from 2 May 2012 to 31 December 2016. For VIIRS_EDR, the AOD observations are obtained from the scientific data set (SDS) “aerosol optical depth at 550 nm” at 6 km resolution, and for Aqua-MODIS, the AOD observations are obtained from the SDS “image optical depth land and ocean” at 3 km (DT3K) and 10 km (DT10K) resolutions, “deep blue aerosol optical depth 550 land” at 10 km resolution (DB10K), and “AOD 550 dark target deep blue combined” at 10 km resolution (DTB10K). Results show that the high-quality (QF = 3) DTB10K performs the best against the CE318 AOD observations, along with a higher R (0.85) and more retrievals within the expected error (EE) ± (0.05 + 15%) (55%). Besides, there is a 10% overestimation, but the positive bias does not exhibit obvious seasonal variations. Similarly, the DT3K and DT10K products overestimate AOD retrievals by 23% and 15%, respectively, all over the year, but the positive biases become larger in spring and summer. For the DB10K AOD retrievals, there is an overestimation (underestimation) in autumn and winter (spring and summer). Compared to the Aqua-MODIS AOD products, the VIIRS_EDR AOD retrievals are less correlated (R = 0.73) and only 44% of the retrievals fall within EE. Meanwhile, the VIIRS_EDR shows larger bias than the Aqua-MODIS C6 retrievals, and tends to overestimate AOD retrievals in summer and underestimate in winter. Additionally, there is an underestimation for the VIIRS_EDR AOD retrievals over the regions during high aerosol loadings. These indicate that the VIIRS_EDR retrieval algorithm needs to be improved in further applications over the YRB.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of VIIRS AOD through a Comparison with a Sun Photometer and MODIS AODs over Wuhan

Visible Infrared Imaging Radiometer Suite (VIIRS) is a next-generation polar-orbiting operational environmental sensor with a capability for global aerosol observations. A comprehensive validation of VIIRS products is significant for improving product quality, assessing environment quality for human life, and studying regional climate change. In this study, three-year (from 1 January 2014 to 31...

متن کامل

Aerosol Optical Depth investigated with satellite remote sensing observations in China

In this study, Aerosol Optical Depth (AOD) at 550nm from the MODIS sensor on board the Terra/Aqua satellites were compared with sun photometer (CE-318) measurements from 11 AERONET stations in China. The average correlation coefficient (R) value from the AOD product, using the Aqua-MODIS Deep Blue algorithm, in the Hexi Corridor was 0.67. The MODIS Dark Target algorithm AOD product is superior ...

متن کامل

Inter-Comparison of S-NPP VIIRS and Aqua MODIS Thermal Emissive Bands Using Hyperspectral Infrared Sounder Measurements as a Transfer Reference

This paper compares the calibration consistency of the spectrally-matched thermal emissive bands (TEB) between the Suomi National Polar-orbiting Partnership (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) and the Aqua Moderate Resolution Imaging Spectroradiometer (MODIS), using observations from their simultaneous nadir overpasses (SNO). Nearly-simultaneous hyperspectral measurements ...

متن کامل

Validation of S-NPP VIIRS Sea Surface Temperature Retrieved from NAVO

The validation of sea surface temperature (SST) retrieved from the new sensor Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-Orbiting Partnership (S-NPP) Satellite is essential for the interpretation, use, and improvement of the new generation SST product. In this study, the magnitude and characteristics of uncertainties in S-NPP VIIRS SST produced by the Nav...

متن کامل

High-resolution (375 m) cloud microstructure as seen from the NPP/VIIRS satellite imager

VIIRS (Visible Infrared Imaging Radiometer Suite), onboard the Suomi NPP (National Polar-orbiting Partnership) satellite, has an improved resolution of 750 m with respect to the 1000 m of the Moderate Resolution Imaging Spectroradiometer for the channels that allow retrieving cloud microphysical parameters such as cloud drop effective radius (re). VIIRS also has an imager with five channels of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Remote Sensing

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2018