Automated real-time detection of tonic-clonic seizures using a wearable EMG device
نویسندگان
چکیده
OBJECTIVE To determine the accuracy of automated detection of generalized tonic-clonic seizures (GTCS) using a wearable surface EMG device. METHODS We prospectively tested the technical performance and diagnostic accuracy of real-time seizure detection using a wearable surface EMG device. The seizure detection algorithm and the cutoff values were prespecified. A total of 71 patients, referred to long-term video-EEG monitoring, on suspicion of GTCS, were recruited in 3 centers. Seizure detection was real-time and fully automated. The reference standard was the evaluation of video-EEG recordings by trained experts, who were blinded to data from the device. Reading the seizure logs from the device was done blinded to all other data. RESULTS The mean recording time per patient was 53.18 hours. Total recording time was 3735.5 hours, and device deficiency time was 193 hours (4.9% of the total time the device was turned on). No adverse events occurred. The sensitivity of the wearable device was 93.8% (30 out of 32 GTCS were detected). Median seizure detection latency was 9 seconds (range -4 to 48 seconds). False alarm rate was 0.67/d. CONCLUSIONS The performance of the wearable EMG device fulfilled the requirements of patients: it detected GTCS with a sensitivity exceeding 90% and detection latency within 30 seconds. CLASSIFICATION OF EVIDENCE This study provides Class II evidence that for people with a history of GTCS, a wearable EMG device accurately detects GTCS (sensitivity 93.8%, false alarm rate 0.67/d).
منابع مشابه
Epileptic seizure detection using Reservoir Computing
In this paper it is shown that Reservoir Computing can be successfully applied to perform real-time detection of epileptic seizures in Electroencephalograms (EEGs). Absence and tonic-clonic seizures are detected on intracranial EEG coming from rats. This resulted in an area under the Receiver Operating Characteristics (ROC) curve of more than 0.99 on the data that was used. For absences an aver...
متن کاملContinuous monitoring of electrodermal activity during epileptic seizures using a wearable sensor Citation
We present a novel method for monitoring sympathetic nervous system activity during epileptic seizures using a wearable sensor measuring electrodermal activity (EDA). The wearable sensor enables long-term, continuous EDA recordings from patients. Preliminary results from our pilot study suggest that epileptic seizures induce a surge in EDA. These changes are greater in generalized tonic-clonic ...
متن کاملDetection of generalized tonic–clonic seizures using surface electromyographic monitoring
OBJECTIVE A prospective multicenter phase III trial was undertaken to evaluate the performance and tolerability in the epilepsy monitoring unit (EMU) of an investigational wearable surface electromyographic (sEMG) monitoring system for the detection of generalized tonic-clonic seizures (GTCSs). METHODS One hundred ninety-nine patients with a history of GTCSs who were admitted to the EMU in 11...
متن کاملPatterns of muscle activation during generalized tonic and tonic-clonic epileptic seizures.
PURPOSE Tonic seizures and the tonic phase of tonic-clonic epileptic seizures are defined as "sustained tonic" muscle contraction lasting a few seconds to minutes. Visual inspection of the surface electromyogram (EMG) during seizures contributed considerably to a better understanding and accurate diagnosis of several seizure types. However, quantitative analysis of the surface EMG during the ep...
متن کاملAutomated Algorithm for Generalized Tonic–Clonic Epileptic Seizure Onset Detection Based on sEMG Zero-Crossing Rate
Patients are not able to call for help during a generalized tonic-clonic epileptic seizure. Our objective was to develop a robust generic algorithm for automatic detection of tonic-clonic seizures, based on surface electromyography (sEMG) signals suitable for a portable device. Twenty-two seizures were analysed from 11 consecutive patients. Our method is based on a high-pass filtering with a cu...
متن کامل