The Correlation of Serum Metal Ions with Functional Outcome Scores at Three-to-Six Years following Large Head Metal-on-Metal Hip Arthroplasty

نویسندگان

  • Sheethal Prasad Patange Subbarao
  • Ibrahim A. Malek
  • Khitish Mohanty
  • Phillip Thomas
  • Alun John
چکیده

Based on success of hip resurfacing, large head Metal on Metal (MoM) hip arthroplasty has gained significant popularity in recent years. There are growing concerns about metal ions related soft tissue abnormalities. The aim of this study was to define a correlation of metal ions with various functional outcome scores following large head MoM hip arthroplasty. Consecutive cohort of 70 patients (76 hips) with large head MoM hip arthroplasty using SL-Plus femoral stem and Cormet acetabular component were prospectively followed up. An independent observer assessed the patients which included serology for metal ion levels and collection of Oxford Hip, Harris hip, WOMAC, SF-36 & modified UCLA scores. Median serum cobalt and chromium levels were 3.10 μg/L (0.35-62.92) and 4.21 μg/L (0.73-69.27) with total of median 7.30 μg/L (2.38-132.19). The median Oxford, Harris, WOMAC, SF-36 and modified UCLA scores were 36 (6-48), 87 (21-100), 36 (24-110), 104 (10-125), and 3 (1-9), respectively. Seventeen patients had elevated serum cobalt and chromium levels ≥7 μg/L. There was no significant correlation between serum metal ion levels with any of these outcome scores. We recommend extreme caution during follow up of these patients with large head MoM arthroplasty.

منابع مشابه

No association between serum metal ions and implant fixation in large-head metal-on-metal total hip arthroplasty

BACKGROUND The mechanism of failure of metal-on-metal (MoM) total hip arthroplasty (THA) has been related to a high rate of metal wear debris, which is partly generated from the head-trunnion interface. However, it is not known whether implant fixation is affected by metal wear debris. PATIENTS AND METHODS 49 cases of MoM THA in 41 patients (10 women) with a mean age of 52 (28-68) years were ...

متن کامل

Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

BACKGROUND Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentr...

متن کامل

Primary metal-on-metal total hip arthroplasty with large-diameter femoral heads: a clinical trial of 59 hips.

Large-diameter femoral heads with nearly anatomical sizes became available for metal-on-metal total hip arthroplasty after recent advances in metal-on-metal technology. We retrospectively studied the clinical and radiological results in 59 hips of 54 patients (32 women and 22 men, mean age 54.4 years) who underwent cementless metal-on-metal total hip arthroplasty with large-diameter heads. Pati...

متن کامل

Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems

BACKGROUND The purpose of the study was twofold: first, to determine whether there is a statistically significant difference in the metal ion levels among three different large-head metal-on-metal (MOM) total hip systems. The second objective was to assess whether position of the implanted prostheses, patient demographics or factors such as activity levels influence overall blood metal ion leve...

متن کامل

Distributed analysis of hip implants using six national and regional registries: comparing metal-on-metal with metal-on-highly cross-linked polyethylene bearings in cementless total hip arthroplasty in young patients.

BACKGROUND The regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013