Performance characteristics of eight estradiol immunoassays.
نویسندگان
چکیده
Measurement of estradiol is useful in assisted reproduction, evaluation of infertility, menopause, and male feminization. The analytic performance of 8 estradiol immunoassays was evaluated. The imprecision and accuracy of the Access, ADVIA Centaur, ARCHITECT i2000, AutoDELFIA, Elecsys 2010, IMMULITE 2000, and Vitros ECi estradiol assays (see text for proprietary information) were evaluated by using an isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) reference method. The coefficient of variation (CV) ranged from 6.9% on the Elecsys 2010 to 42.6% on the ADVIA Centaur at an estradiol concentration of 18 pg/mL (66 pmol/L), with the ARCHITECT i2000 assay in development and the Vitros ECi having a CV below 10% at this estradiol concentration. Agreement between the automated assays and ID-GC-MS was variable, with slopes ranging from 0.87 to 1.20. The Access, ARCHITECT i2000 in development, and the IMMULITE 2000 were the most accurate, with slopes of 0.99, 0.98, and 1.03, respectively. These findings indicate that the ARCHITECT i2000 estradiol assay in development had the best precision and accuracy of the assays evaluated for measurement of serum estradiol concentrations.
منابع مشابه
Performance characteristics of three automated immunoassays for thyroid hormones
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...
متن کاملPerformance of direct estradiol immunoassays with human male serum samples.
BACKGROUND Steroid immunoassays originally required solvent extraction, chromatography, and structurally authentic tracers to avoid interference from steroid cross-reactivity and matrix effects. The demand for steroid assays has driven assay simplification, bypassing this triplet of validity criteria to allow use of unextracted serum, which has introduced bias and nonspecificity at low steroid ...
متن کاملThe effect of injection of estradiol benzoate into hippocampal CA1 area on spatial learning and memory in intact and castrated adult male rats
Estrogen has a widespread and complex influence on brain capabilities such as learning and memory. On the other hand, hippocampus as one of the main brain structures has an important role in spatial information processing. There is some evidence on the existence of estrogen receptors in the hippocampal CA1 area. So, in this study the effect of intrahippocampal injection of estradiol benzoate on...
متن کاملA purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children.
OBJECTIVE To test the clinical usefulness of sensitive commercial immunoassays for determination of low 17beta-estradiol concentrations in children. METHODS The lower limit of detection and clinical usefulness (functional sensitivity) of three commercial estradiol immunoassays were validated by use of 500 sera from prepubertal and pubertal children and 55 pooled sera. The three immunoassays c...
متن کاملA convenient homogeneous enzyme immunoassay for estradiol detection.
A convenient homogeneous enzyme immunoassay for estradiol is described. Unlike heterogeneous immunoassays, which require time-consuming separation steps or expensive automated systems, homogeneous immunoassays, wherein all reagents are freely suspended in bulk solution, can be simple and fast without costly instrumentation. The key component of this assay system, an estradiol-reporter enzyme co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of clinical pathology
دوره 122 3 شماره
صفحات -
تاریخ انتشار 2004