FPGA Based Digital System for Detection of Dicrotic Notch in the Carotid Pulse Signal

نویسندگان

  • Sheikh Md. Rabiul Islam
  • Shumit Saha
  • Md. Imran Khan
چکیده

Heart disease is one of the leading causes of death in human beings. A survey shows every year about 900,000 peoples die due to heart diseases worldwide. Carotid pulse is a pressure signal recorded over the carotid artery as it passes near the surface of the body at the neck. An abnormal carotid pulse called the dicrotic pulse occurs when patients suffer from sepsis, hypovolemic shock, cardiac tamponade, aortic stenosis. Dicrotic notch usually denotes a very low stroke volume, particularly in patients with dilated cardiomyopathy. Lehner and Rangayyan proposed a methodology to detect this dicrotic notch in the carotid pulse signal. This method used the least-squares estimate of the second derivative because a first-derivative operation would give an almost-constant output for the downward slope. In this paper, a digital system is designed to detect the dicrotic notch in the carotid pulse using Verilog Hardware Description Language. Hardware description languages such as Verilog differ from software programming languages because they include ways of describing the propagation of time and signal dependencies (sensitivity). Verilog modules that conform to a synthesizable coding-style, known as RTL (register transfer level), can be physically realized by synthesis software. Synthesis-software algorithmically transforms the Verilog source code into a netlist, a logically-equivalent description consisting only of elementary logic primitives (AND, OR, NOT, flip-flops, etc.) that are available in a specific FPGA or VLSI technology. Further manipulations to the netlist ultimately lead to a circuit fabrication blueprint. Here architecture of a digital system for detection of dicrotic notch in the carotid pulse signal has been proposed by using Verilog HDL based XILINX FPGA board. By this system patients can check his carotid pulse immediately after he feel sick without getting himself admitted in hospital which can save many lives.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Implementation of Digital Demodulator for Frequency Modulated CW Radar (RESEARCH NOTE)

Radar Signal Processing has been an interesting area of research for realization of programmable digital signal processor using VLSI design techniques. Digital Signal Processing (DSP) algorithms have been an integral design methodology for implementation of high speed application specific real-time systems especially for high resolution radar. CORDIC algorithm, in recent times, is turned out to...

متن کامل

Mechanism of the dicrotic pulse.

The dicrotic pulse is an abnormal carotid pulse found in conjunction with certain conditions characterised by low cardiac output. It is distinguished by two palpable pulsations, the second of which is diastolic and immediately follows the second heart sound. In the course of open chest canine studies of the second heart sound, micromanometers and an electromagnetic flow meter were used to study...

متن کامل

The dicrotic arterial pulse.

SUMMARY The study consisted of observations on nine male patients with palpable dicrotic carotid pulses. Average patient age was 37 years. All had advanced myocardial failure as evidenced by cardiomegaly and the presence of prominent atrial and ventricular diastolic gallop sounds. Most of these patients were diagnosed as having primary myocardial disease. The indirect carotid pulse was characte...

متن کامل

Association of common carotid artery Doppler-determined dicrotic notch velocity with the left ventricular ejection fraction.

OBJECTIVES The appearance of the dicrotic notch on blood pressure tracings is associated with impaired cardiac function. Common carotid artery waveforms have similar fiduciary markers, yet they have not been related to cardiac function. We studied associations of common carotid artery dicrotic notch velocities with the left ventricular ejection fraction (LVEF) determined by echocardiography. ...

متن کامل

Nitric oxide is released into circulation with whole-body, periodic acceleration.

STUDY OBJECTIVE To determine if comfortably applied, whole-body, periodic acceleration releases significant amounts of nitric oxide (NO) into the circulation of healthy subjects and patients with inflammatory diseases. MATERIALS Fourteen healthy adults and 40 adult patients with inflammatory diseases underwent single 45-min trials of whole-body, periodic acceleration with a new "passive exerc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013