Giant Aortic Pseudoaneurysm with Stanford Type A Aortic Dissection after Aortic Valve Replacement

نویسندگان

  • Mertay Boran
  • Ali İhsan Parlar
  • Ertay Boran
چکیده

Giant pseudoaneurysm of the ascending aorta is a rare but dreadful complication occurring several months or years after aortic surgery. Thoracic aortic aneurysms tend to be asymptomatic and were previously often diagnosed only after a complication such as dissection or rupture. We present a rare case of giant ascending aneurysm with Stanford type A aortic dissection occurring 6 years after aortic valve replacement and also illustrate the potential dimensions the ascending aorta may reach by a pseudoaneurysm and dissection after AVR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report

Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...

متن کامل

Rupture of equine pericardial aortic-root patch after aortic valve replacement with aortic annulus enlargement: a case report

There are no previous reports of rupture of a heterologous pericardial patch after aortic annulus enlargement. Our patient, a 72-year-old Japanese female, presented with congestive heart failure resulting from heart compression from pseudoaneurysm formation in the aortic root. At 57 years of age the patient had undergone replacement of the ascending aorta for Stanford type A acute aortic dissec...

متن کامل

Formation of pseudoaneurysm after aortic valve replacement without previous endocarditis: a case-control study.

BACKGROUND The aim of this study was to identify the predisposing factors for pseudoaneurysm formation after aortic valve replacement without previous endocarditis. METHODS Echocardiography was used to identify patients. Parameters with influence on the occurrence of pseudoaneurysms were analyzed, and the odds ratio for the influence of the type of valve was estimated. The chi2 goodness-of-fi...

متن کامل

Aorto-Cutaneous Fistula and False Aneurysm of the Ascending Aorta Five Years after its Prosthetic Replacement for Stanford Type A Acute Aortic Dissection.

Aorto-cutaneous fistula and false aneurysm of the ascending aorta in patients who previously underwent Stanford Type A acute aortic dissection are rare and severe complications. Surgical correction remains a demanding challenge. In a case of false aneurysm rupture during redo sternotomy, selective cannulation of the right axillary and left carotid arteries allowed an efficient method of cerebra...

متن کامل

Stanford type A aortic dissection after urgent prosthetic valve replacement: case reports

Occurrence of acute aortic dissection after aortic valve replacement is rare, however, it is associated with high mortality and morbidity rates. We report two Asian cases in which acute aortic dissection occurred after urgent aortic valve replacement for infective endocarditis. Successful graft replacement was carried out with preservation of the prosthetic valves in both cases. Our experience ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012