Comparison of two commercial assays with expert microscopy for confirmation of symptomatically diagnosed malaria.
نویسندگان
چکیده
Conventional light microscopy has been the established method for malaria diagnosis. However, recently several nonmicroscopic rapid diagnostic tests have been developed for situations in which reliable microscopy may not be available. This study was conducted to evaluate the diagnostic performance of a recently introduced ICT Malaria Pf/Pv test. This assay detects Plasmodium falciparum histidine-rich protein 2 antigen (PfHRP-2) for P. falciparum diagnosis and pan-malarial antigen for P. vivax diagnosis. In this study we compared the performance of ICT Malaria Pf/Pv with microscopy of Giemsa-stained blood films and with an OptiMAL test that detects Plasmodium lactate dehydrogenase (pLDH) antigen. A total of 750 clinically suspected malaria patients were examined at local health centers in Kuwait. Both the antigen tests had a high degree of specificity (>98%) for detection of malaria infection. However, they were less sensitive than microscopy. Compared with microscopy the ICT Malaria PF/pf test failed to detect malaria infection in 93 (34%) of 271 malaria patients (11% of patients with P. falciparum and 37% of patients with P. vivax) and the OptiMAL test failed to detect malaria infection in 41 (15%) of 271 malaria patients (7% of patients with P. falciparum and 13% of patients with P. vivax). The sensitivities of the ICT Malaria Pf/Pv and OptiMAL tests for detection of P. falciparum infection were 81 and 87%, and those for detecting P. vivax were 58 to 79%, respectively. The sensitivity of the ICT Malaria Pf/Pv and OptiMAL tests decreased significantly to 23 and 44%, respectively, at parasite densities of <500/ micro l. Both of the tests also produced a number of false-positive results. Overall, the performance of the OptiMAL test was better than that of the ICT Malaria Pf/Pv test. However, our results raise particular concern over the sensitivity of the ICT Malaria Pf/Pv test for detection of P. vivax infection. Further developments appear necessary to improve the performance of the ICT Malaria Pf/Pv test.
منابع مشابه
Misuse of Artemisinin Combination Therapies by Clients of Medicine Retailers Suspected to Have Malaria Without Prior Parasitological Confirmation in Nigeria
Background Prompt and effective case detection and treatment are vital components of the malaria case management strategy as malaria-endemic countries implement the testing, treating and tracking policy. The implementation of this policy in public and formal private sectors continue to receive great attention while the informal private retail sector (mostly the patent and propriety medicine ven...
متن کاملComparison of Western blotting and PCR assays for confirmation of HTLV-1 virus in volunteer blood donors
Abstract Background and Objectives Human T-cell lymphotropic virus type I (HTLV-I) has been associated with two diseases in humans such as adult T-cell leukemia/lymphoma (ATLL) and HTLV-associated myelopathy/tropical spastic Para paresis (HAM/TSP). About 5 to 10 million people are infected with HTLV-1 worldwide. In order to improve the blood safety and to prevent false positive results in bloo...
متن کاملCost-Effectiveness analysis of malaria diagnosis techniques in patients with suspected malaria in Hormozgan province- 2012
Introduction: Since ancient times Malaria in Iran has been considered as a serious health risk, especially in Hormozgan Province, as no other disease like Malaria has imposed irreparable financial and life losses to the country. Since saving costs in the healthcare sector comes as first priority in most countries, this study aims at launching a cost-effectiveness analysis on malaria diagnosis d...
متن کاملEvaluation of the ICT malaria P.f/P.v and the OptiMal rapid diagnostic tests for malaria in febrile returned travellers.
Rapid diagnostic tests (RDTs) are less reliant on expert microscopy and have the potential to reduce errors in malaria diagnosis but have not been extensively evaluated in nonimmune persons or in countries where infection is not endemic. We evaluated the ICT P.f/P.v (ICT-Amrad, Sydney, Australia) and OptiMal (Flow Inc., Portland, Oreg.) assays prospectively for the diagnosis of malaria in 158 s...
متن کاملA comparison of three diagnostic techniques for malaria: a rapid diagnostic test (NOW Malaria), PCR and microscopy.
Malaria is a common, life-threatening infection in endemic tropical areas and one that presents a diagnostic challenge to laboratories in most non-endemic countries. A rapid and accurate diagnosis is a prerequisite for effective treatment, especially for the potentially fatal cases of Plasmodium falciparum infection. In the present, multi-centre study, the performances of a rapid diagnostic tes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 40 12 شماره
صفحات -
تاریخ انتشار 2002