Simultaneous tracheal and oesophageal pH monitoring during mechanical ventilation.
نویسندگان
چکیده
OBJECTIVE To simultaneously record tracheal and oesophageal pH in mechanically ventilated children to determine: (1) the feasibility and safety of the method; (2) the incidence of gastro-oesophageal reflux (GOR) and pulmonary contamination; and (3) their associated risk factors. DESIGN Prospective study. SETTING Paediatric intensive care unit in a university hospital. PATIENTS Twenty mechanically ventilated children (mean age 6.7 years) who met the following inclusion criteria: endotracheal tube with an internal diameter of 4 mm or more (cuffed or uncuffed), mechanical ventilation for an acute disease, no treatment with antiacids, prokinetics, or H2-receptor blockers, and no nasogastric or orogastric tube. METHODS The tracheal antimony pH probe was positioned 1 cm below the distal end of the endotracheal tube. The oesophageal antimony pH probe was positioned at the lower third of the oesophagus. pH was recorded on a double channel recorder and analysed with EsopHogram 5.01 software and by examination of the trace. The following definitions were used: GOR index, percentage of time pH < 4; pathological GOR, GOR index > 4.8%; tracheal reflux, fall in tracheal pH < 4, 4.5, or 5, or a decrease of one unit from baseline, in both cases preceded by an episode of GOR. The results were analysed statistically by Fisher's exact and the Kruskal-Wallis test. RESULTS The procedure was well tolerated and the median duration of analysable recording was 6 hours (range 5-22.6). Pathological GOR was observed in eight (40%) children. GOR was more frequent with an uncuffed endotracheal tube than with a cuffed one (p = 0.01). Tracheal reflux (pH < 4) was observed in four children (20%) without clinical evidence of pulmonary aspiration. Episodes of tracheal reflux were associated with a GOR index > 10% (p < 0.01) and were more frequent with a maximal inspiratory pressure of < 25 cm H2O (p = 0.03), but were not related to the indication for mechanical ventilation, whether the endotracheal tube was cuffed or not, age, or drug treatment. CONCLUSIONS Simultaneous tracheal and oesophageal pH monitoring was feasible in the setting of this study. Tracheal reflux can occur without pathological GOR, and GOR may occur without tracheal reflux. Further prospective studies in larger groups of patients are now justified.
منابع مشابه
Does mechanical ventilation precipitate gastro-oesophageal reflux during enteral feeding?
The influence of intermittent positive pressure ventilation on gastro-oesophageal reflux in preterm infants is not known. In many neonatal units, however, concern that ventilation may increase gastro-oesophageal reflux (and therefore aspiration) leads to avoidance of enteral feeding during ventilation. We have therefore performed a crossover study of gastrooesophageal reflux by monitoring lower...
متن کاملSimultaneous tracheal and oesophageal pH measurements in asthmatic patients with gastro-oesophageal reflux.
BACKGROUND An association between asthma and gastro-oesophageal reflux is well recognised but the underlying mechanism is unclear. One suggestion is that gastric juice is aspirated into the tracheal and upper airways but detection of these events is difficult and involves radioisotopic studies. A new method of making direct measurements of tracheal and oesophageal pH over a 24 hour period is de...
متن کاملECG record during changes in oesophageal pH.
Seventeen patients with non-cardiac chest pain were investigated by simultaneous ambulatory 24 hour ECG and oesophageal pH monitoring. While 11 patients lowered their oesophageal pH below 4 for a significant percentage, (3.4%) of recorded time and experienced chest pain, no simultaneous ECG changes occurred. In 10 patients chest pain was reproduced by an oesophageal acid perfusion test (Bernste...
متن کاملComparison of end-tidal carbon dioxide, oxygen saturation and clinical signs for the detection of oesophageal intubation.
The reliability of various methods for detecting oesophageal intubation was assessed by means of a single blind study in rats. Both oesophagus and trachea were simultaneously intubated. The presence or absence of various clinical signs was noted during tracheal or oesophageal ventilation and arterial blood gases and end-tidal CO2 were measured. Oesophageal ventilation for one minute was associa...
متن کاملAccuracy and precision of "deep sternal" and tracheal temperatures at high- and low-fresh-gas flows.
The accuracy of tracheal temperature as a measure of core temperature is relatively poor during high-flow ventilation (6 litre min-1 fresh-gas flow). It is unknown if accuracy improves when lower fresh-gas flow rates are used. We tested the hypothesis that tracheal temperature accuracy would improve with low-flow ventilation (1 litre min-1). We studied 20 ASA Physical Status I and II patients u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood
دوره 75 1 شماره
صفحات -
تاریخ انتشار 1996