Intrafractional prostate motion during external beam radiotherapy monitored by a real‐time target localization system

نویسندگان

  • Xu Tong
  • Xiaoming Chen
  • Jinsheng Li
  • Qianqian Xu
  • Mu‐han Lin
  • Lili Chen
  • Robert A. Price
  • Chang‐Ming Ma
چکیده

This paper investigates the clinical significance of real-time monitoring of intrafractional prostate motion during external beam radiotherapy using a commercial 4D localization system. Intrafractional prostate motion was tracked during 8,660 treatment fractions for 236 patients. The following statistics were analyzed: 1) the percentage of fractions in which the prostate shifted 2-7 mm for a certain duration; 2) the proportion of the entire tracking time during which the prostate shifted 2-7mm; and 3) the proportion of each minute in which the shift exceeded 2-7 mm. The ten patients exhibiting maximum intrafractional-motion patterns were analyzed separately. Our results showed that the percentage of fractions in which the prostate shifted by > 2, 3, 5, and 7 mm off the baseline in any direction for > 30 s was 56.8%, 27.2%, 4.6%, and 0.7% for intact prostate and 68.7%, 35.6%, 10.1%, and 1.8% for postprostatectomy patients, respectively. For the ten patients, these percentages were 91.3%, 72.4%, 36.3%, and 6%, respectively. The percentage of tracking time during which the prostate shifted > 2, 3, 5, and 7 mm was 27.8%, 10.7%, 1.6%, and 0.3%, respectively, and it was 56.2%, 33.7%, 11.2%, and 2.1%, respectively, for the ten patients. The percentage of tracking time for a > 3 mm posterior motion was four to five times higher than that in other directions. For treatments completed in 5 min (VMAT) and 10 min (IMRT), the proportion for the prostate to shift by > 3mm was 4% and 12%, respectively. Although intrafractional prostate motion was generally small, caution should be taken for patients who exhibit frequent large intrafractional motion. For those patients, adjustment of patient positioning may be necessary or a larger treatment margin may be used. After the initial alignment, the likelihood of prostate motion increases with time. Therefore, it is favorable to use advanced techniques (e.g., VMAT) that require less delivery time in order to reduce the treatment uncertainty resulting from intrafractional prostate motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

Intrafractional Tracking Accuracy of a Transperineal Ultrasound Image Guidance System for Prostate Radiotherapy

PURPOSE The aim of this study is to evaluate the tracking accuracy of a commercial ultrasound system under relevant treatment conditions and demonstrate its clinical utility for detecting significant treatment deviations arising from inadvertent intrafractional target motion. METHODS A multimodality male pelvic phantom was used to simulate prostate image-guided radiotherapy with the system un...

متن کامل

A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates

Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...

متن کامل

Obesity does not influence prostate intrafractional motion

INTRODUCTION Motion of the prostate is problematic in the accurate delivery of external beam radiation therapy (EBRT) for prostate cancer. This study investigated the relationship between body mass index (BMI), an easily measured indicator of obesity, and prostate motion. METHODS Prostate motion during EBRT was assessed by measuring the displacement of fiducial markers implanted within the pr...

متن کامل

Impact of Intrafractional Prostate Motion on the Accuracy and Efficiency of Prostate Cancer Treatment on CyberKnife Radiotherapy

One of the most common treatments for men with localized prostate cancer is radiation therapy, which involves delivering small doses of radiation to the prostate for an extended period of time. Stereotactic-body radiation therapy (SBRT) is a form of radiotherapy that delivers increased dosage to the prostate with more precision. The results are shorter treatment times, increased effectiveness, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015