Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds: Two-year clinical outcomes of the EVERBIO II trial.

نویسندگان

  • Diego Arroyo
  • Gregoire Gendre
  • Sara Schukraft
  • Zacharenia Kallinikou
  • Olivier Müller
  • Gérard Baeriswyl
  • Jean-Christophe Stauffer
  • Jean-Jacques Goy
  • Mario Togni
  • Stéphane Cook
  • Serban Puricel
چکیده

BACKGROUND Data from randomized controlled trials have shown that the ABSORB BVS is non-inferior to Cobalt Chromium everolimus-eluting stents at 2years. METHODS & RESULTS The EVERBIO II trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) is a single-center, assessor-blind, randomized controlled trial enrolling 240 patients with an allocation ration of 1:1:1 conducted at University and Hospital Fribourg, Switzerland. The studied devices were an everolimus-eluting persistent polymer stent (EES), a biolimus-eluting stent with bioabsorbable polymer (BES) and a fully bioresorbable vascular scaffold (BVS). Clinical end points collected at 9months, 12months, and 2years, were academic research consortium defined composites, device thrombosis and target-vessel revascularization. Clinical follow-up at 2years was available in 96% (N=77) of patients in the EES group, in 100% (N=80) in the BES and 99% (N=77) in the BVS group. The device-oriented composite end point of cardiac death, target-vessel myocardial infarction and target-lesion revascularization occurred in 13 (16%) patients treated with EES, in 7 (9%) patients treated with BES and in 16 (21%) patients treated with BVS. There was no significant difference when the metallic stents were compared to the BVS (p=0.12). There was one late scaffold thrombosis throughout the trial in the BVS group, and no definite stent thrombosis in either EES or BES treated patients. CONCLUSIONS The current analysis shows no significant differences with regard to clinical outcomes at 2years between BVS and the best-in-class metallic DES. Event rates were numerically higher in BVS-treated patients. However, when BVS were compared to BES alone, the occurrence of device related adverse events was significantly increased.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of everolimus-eluting and biolimus-eluting coronary stents with everolimus-eluting bioresorbable scaffold: study protocol of the randomized controlled EVERBIO II trial

BACKGROUND Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The ...

متن کامل

Comparison of Everolimus- and Biolimus-Eluting Coronary Stents With€Everolimus-Eluting Bioresorbable Vascular Scaffolds

Fro ini Du an res da Bio (CR Lis Yo Ma BACKGROUND The first CE-approved bioresorbable vascular scaffold (BVS) is effective at treating simple lesions and stable coronary artery disease, but it has yet to be assessed versus the best-in-class drug-eluting stents (DES). OBJECTIVES This study sought to compare the performance of a BVS with that of everolimus-eluting stents (EES) and biolimus-elutin...

متن کامل

Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents

Second-generation metallic drug-eluting stents (DES) have been widely recommended for percutaneous coronary intervention. One of the main drawbacks of these devices is the risk of late adverse events (ie, beyond 1 year), particularly repeat revascularization, which are partly related to the persistence of the metallic stents in the coronary artery wall. In this context, the bioresorbable vascul...

متن کامل

Tension gastrothorax mimicking acute coronary syndrome and causing cardiac arrest.

Veldhof S, Rapoza R, Onuma Y, Garcia-Garcia HM, Chevalier B. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary art...

متن کامل

Clinical Outcomes From The Bioresorbable Vascular Scaffold: Is There A Role for Them?

The risk of stent thrombosis and restenosis with the second generation drug eluting stents remains. The bioresorbable vascular scaffold is a third generation stent and overcomes the problems associated with drug eluting metallic stents. The bioresorbable vascular scaffold completely absorbs within the coronary vessel over 3-5 years. Multiple trials in patients with non complex coronary disease ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of cardiology

دوره 243  شماره 

صفحات  -

تاریخ انتشار 2015