Compensation of impedance meters, when using an external front-end amplifier

نویسندگان

  • Josep Maria Torrents
  • Ramon Pallàs-Areny
چکیده

Four-terminal impedance meters based on pseudo-bridges yield unexpected uncertainties when using high-contact-impedance electrodes. Adding a front-end amplifier to the impedance meter and rearranging the connection of the meter terminals overcome the contact impedance problem. However, because the compensation provisions in the instrument are meant to compensate only impedance residuals of test fixtures, by either an open/short or an open/short/load correction procedure, the external front-end increases the inaccuracy of the measurement setup. This paper shows that an open/short/load correction can also compensate complicated impedance residuals such as those from external amplifiers. The paper details the correction procedure and provides the equations to calculate the impedance under test from the readings of the impedance meter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-Widband Distributed Amplifier Using Loss Compensation Technique on Both Input and Output Circuit

In this paper, we analyze a distributed amplifier based on input/output attenuation compensation. The analysis is carried out for a HEMT transistor; and a constant-k section filter is used to calculate the amplifier’s characteristics such as attenuation factor, phase constant and gain. The proposed design approach enables us to examine the tradeoff among the variables, which include the type an...

متن کامل

Fully Integrated Biopotential Acquisition Analog Front-End IC

A biopotential acquisition analog front-end (AFE) integrated circuit (IC) is presented. The biopotential AFE includes a capacitively coupled chopper instrumentation amplifier (CCIA) to achieve low input referred noise (IRN) and to block unwanted DC potential signals. A DC servo loop (DSL) is designed to minimize the offset voltage in the chopper amplifier and low frequency respiration artifacts...

متن کامل

Study and Analysis of A Simple Self Cascode Regulated Cascode Amplifier

This article proposed a simple self cascode RGC amplifier configuration to increase the gain and bandwidth. The cascode amplifier eliminates the miller capacitance between input and output and facilitates high gain, high input and output impedance with high bandwidth. However, the cascode amplifier requires relatively high supply voltage for proper operation and it decreases the output voltage ...

متن کامل

Nano Scale Low Power Chopper Amplifier using Cascode and Miller Compensation Nutrilization in 45 nm CMOS

In this paper, reduced power consumption, low-noise CMOS amplifier using chopper technique is designed, chopper-equalized amplifier had been used as a front end of a voltage-to-frequency converter instrument which performs pretty well, and they were meeting just about every specification, but they had a problem with undesired and unpleasant little offset shifts and jumps. Trying to solve this p...

متن کامل

Low flicker-noise DC amplifier for 50 Ω sources

This article analyzes the design of a low-noise amplifier intended as the input front-end for the measurement of the low-frequency components (below 10 Hz) of a 50 Ω source. Low residual flicker is the main desired performance. This feature can only be appreciated if white noise is sufficiently low, and if an appropriate design ensures dc stability. An optimal solution is proposed, in which the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE Trans. Instrumentation and Measurement

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2002