Arterial wave speed is widely used to determine arterial distensibility and has been utilised as a surrogate marker for vascular disease. A comparison between the results of the traditional foot-to-foot method for measuring wave speed to those of the pressure-velocity loop (PU-loop) method is one of the primary objectives of this paper. We also investigate the regional wave speed along the aorta, and the effect of arterial occlusion on the PU-loop measured in the ascending aorta. In 11 anaesthetised dogs, a total occlusion lasting 3 min was produced at four sites: upper thoracic, diaphragm, abdominal and left iliac artery. Pressure and flow in the ascending aorta and pressure proximal to the occlusion site were measured, and data were collected before, during the occlusion and after the occlusion had been removed. In control conditions, the wave speeds determined by the PU-loop in the aortic root were systematically lower than those measured by the foot-to-foot method. During thoracic and diaphragm occlusions, mean aortic pressure and wave speed increased significantly but returned to control values after each occlusion had been removed. The PU-loop is an objective and easy to use method for determining wave speed and can be advantageous for use in short arterial segments when local measurements of pressure and velocity are available.
منابع مشابه
Wave intensity in the ascending aorta: effects of arterial occlusion.
We examine the effects of arterial occlusion on the pressure, velocity and the reflected waves in the ascending aorta using wave intensity analysis. In 11 anaesthetised, open-chested dogs, snares were used to produce total arterial occlusion at 4 sites: the upper descending aorta at the level of the aortic valve (thoracic); the lower thoracic aorta at the level of the diaphragm (diaphragm); the...
متن کاملRegional wave travel and reflections along the human aorta: a study with six simultaneous micromanometric pressures.
The human aorta and its terminal branches were investigated in normal subjects during elective cardiac catheterization to evaluate regional wave travel and arterial wave reflections. A specially designed catheter with six micromanometers equally spaced at 10 cm intervals was positioned with the tip sensor in the distal external iliac artery and the proximal sensor in the aortic arch. Simultaneo...
متن کاملReservoir and reservoir-less pressure effects on arterial waves in the canine aorta.
BACKGROUND A time-domain approach to couple the Windkessel effect and wave propagation has been recently introduced. The technique assumes that the measured pressure in the aorta (P) is the sum of a reservoir pressure (Pr), due to the storage of blood, and an excess pressure (Pe), due to the waves. Since the subtraction of Pr from P results in a smaller component of Pe, we hypothesized that usi...
متن کاملAORTIC ELASTICITY Regional wave travel and reflections along the human aorta : a study with six simultaneous micromanometric pressures
The human aorta and its terminal branches were investigated in normal subjects during elective cardiac catheterization to evaluate regional wave travel and arterial wave reflections. A specially designed catheter with six micromanometers equally spaced at 10 cm intervals was positioned with the tip sensor in the distal external iliac artery and the proximal sensor in the aortic arch. Simultaneo...
متن کاملAORTIC ELASTICITY Regional wave travel and reflections along
The human aorta and its terminal branches were investigated in normal subjects during elective cardiac catheterization to evaluate regional wave travel and arterial wave reflections. A specially designed catheter with six micromanometers equally spaced at 10 cm intervals was positioned with the tip sensor in the distal external iliac artery and the proximal sensor in the aortic arch. Simultaneo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical engineering & physics
دوره 26 1 شماره
صفحات -
تاریخ انتشار 2004