Markerless Lung Tumor Motion Tracking by Dynamic Decomposition of X-Ray Image Intensity

نویسندگان

  • Noriyasu Homma
  • Yoshihiro Takai
  • Haruna Endo
  • Kei Ichiji
  • Yuichiro Narita
  • Xiaoyong Zhang
  • Masao Sakai
  • Makoto Osanai
  • Makoto Abe
  • Norihiro Sugita
  • Makoto Yoshizawa
چکیده

We propose a new markerless tracking technique of lung tumor motion by using an X-ray fluoroscopic image sequence for real-time image-guided radiation therapy (IGRT). A core innovation of the new technique is to extract a moving tumor intensity component from the fluoroscopic image intensity. The fluoroscopic intensity is the superimposition of intensity components of all the structures passed through by the X-ray. The tumor can then be extracted by decomposing the fluoroscopic intensity into the tumor intensity component and the others. The decomposition problem for more than two structures is ill posed, but it can be transformed into a well-posed one by temporally accumulating constraints that must be satisfied by the decomposed moving tumor component and the rest of the intensity components. The extracted tumor image can then be used to achieve accurate tumor motion tracking without implanted markers that are widely used in the current tracking techniques. The performance evaluation showed that the extraction error was sufficiently small and the extracted tumor tracking achieved a high and sufficient accuracy less than 1 mm for clinical datasets. These results clearly demonstrate the usefulness of the proposed method for markerless tumor motion tracking.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback

Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...

متن کامل

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

A Tracking Method of Invisible Tumors Using Surrounding Features on Time Series X-ray Images

Purpose In radiotherapy, fiducial markers are often used as internal surrogate to localize a lung tumor position. Placement of the fiducial markers impose additional invasion on patients. Meanwhile, several studies have been devoted to the development of markerless tracking of tumors on X-ray images [1][2]. A recent study reports that visible tumors can be tracked to an accuracy of less than 2 ...

متن کامل

Development and Investigation of Intensity-modulated Radiation Therapy Treatment Planning for Four-dimensional Anatomy

Lung cancer is the leading cause of cancer-related deaths worldwide. Radiotherapy is one of the main treatment modalities of lung cancer. However, the achievable accuracy of radiotherapy treatment is limited for lung-based tumors due to respiratory motion. Four-dimensional (4D) radiotherapy explicitly accounts for anatomic motion by characterizing the motion, creating a treatment plan that acco...

متن کامل

Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy.

Accurate lung tumor tracking in real time is a keystone to image-guided radiotherapy of lung cancers. Existing lung tumor tracking approaches can be roughly grouped into three categories: (1) deriving tumor position from external surrogates; (2) tracking implanted fiducial markers fluoroscopically or electromagnetically; (3) fluoroscopically tracking lung tumor without implanted fiducial marker...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013