LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
نویسندگان
چکیده
A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5 μm). The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v). Linear calibration curves were obtained in the concentration range of 1-2000.0 ng/mL, with a lower limit of quantification of 0.99 ng/mL. The intra- and interday precision (RSD) values were below 3%. The method was successfully applied to a bioequivalence study of creatinine in Chinese smokers and nonsmokers. The total cotinine in 24 h urine and cotinine : creatinine ratio were also positively associated (Pearson R = 0.942, P < 0.0001). However, cotinine : creatinine ratio varied significantly across smoking groups for the difference of individual. 24 h urinary cotinine was more appropriate for expressing correlation with tar than cotinine : creatinine ratio.
منابع مشابه
Creatinine measurements in 24 h urine by liquid chromatography--tandem Mass Spectrometry.
A simple, sensitive, and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determining urinary creatinine was developed and used to evaluate 24 h urine samples collected during an exposure study. Urine (1 microL) was diluted with methanol and then directly applied to LC-MS/MS. Under electrospray ionization (ESI) conditions, the transition molecules of creatinine and ...
متن کاملTandem mass spectrometry measurements of creatinine in mouse plasma and urine for determining glomerular filtration rate.
Endogenous creatinine clearance (Ccr) is widely accepted as an estimate of glomerular filtration rate (GFR), the best overall biomarker of kidney function. However, current common methods of measuring creatinine are not sensitive enough for mouse plasma. Accordingly, we here report a new method of measuring creatinine by liquid chromatography tandem mass spectrometry (LC-MS/MS) using deuterated...
متن کاملEvaluation of Serum Cotinine Cut-Off to Distinguish Smokers From Nonsmokers in the Korean Population
BACKGROUND Cotinine has been widely used as an objective marker to identify current smokers. We conducted this study to address the absence of Korean studies investigating the efficacy of immunoassays and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the detection of serum cotinine and to determine the optimal serum cotinine cut-off level for differentiating current smokers from...
متن کاملEvaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease
Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...
متن کاملDetermination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry
A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department of Health, Public Health Laboratories (PHL). 50 µL of urine was mixed with a 1 : 1 acetonitrile/wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012