Use of the trauma pelvic orthotic device (T-POD) for provisional stabilisation of anterior-posterior compression type pelvic fractures: a cadaveric study.

نویسندگان

  • Nicola A DeAngelis
  • John J Wixted
  • Jacob Drew
  • Mark S Eskander
  • Jonathan P Eskander
  • Bruce G French
چکیده

OBJECTIVE To demonstrate that a commercially available pelvic binder the trauma pelvic orthotic device (T-POD) is an effective way to provisionally stabilise anterior-posterior compression type pelvic injuries. METHODS Rotationally unstable pelvic injuries were created in 12 non-embalmed human cadaveric specimens. Each pelvis was then stabilised first with a standard bed sheet wrapped circumferentially around the pelvis and held in place with a clamp. After recreating the symphyseal diastasis, the pelvis was stabilised with the T-POD. Reduction of the symphyseal diastasis was assessed by comparing measurements obtained via pre- and post-stabilisation AP radiographs. RESULTS The mean symphyseal diastasis was reduced from 39.3mm (95% CI 30.95-47.55) to 17.4mm (95% CI -0.14 to 34.98) with the bed sheet, and to 7.1mm (95% CI -2.19 to 16.35) with the T-POD. CONCLUSIONS Although both a circumferential sheet and the T-POD were able to decrease symphyseal diastasis consistently, only the T-POD showed a statistically significant improvement in diastasis when compared to injury measurements. In 75% of the cadaveric specimens (9 of 12), the T-POD was able to reduce the symphysis to normal (<10mm diastasis). Both a circumferential sheet and the T-POD are effective in provisionally stabilising Burgess and Young anterior-posterior compression II type pelvic injuries, but the T-POD is more effective in reducing symphyseal diastasis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of a new pelvic stabilizer (T-POD®) on reduction of pelvic volume and haemodynamic stability in unstable pelvic fractures.

BACKGROUND Pelvic fractures, often the result of high energy blunt trauma, are associated with severe morbidity and mortality. A new pelvic stabilizer (T-POD®) provides secure and effective simultaneous circumferential compression of the pelvis. METHODS In this study we describe 15 patients with a prehospital untreated unstable pelvic fracture with signs of hypovolaemic shock with the T-POD®....

متن کامل

Emergent pelvic fixation in patients with exsanguinating pelvic fractures.

BACKGROUND An alternative to embolization or external pelvic fixation (EPF) in patients with multiple pelvic fractures and hemorrhage is a pelvic orthotic device (POD), which may easily be placed in the resuscitation area. Little published information is available about its effectiveness. This study evaluated the efficacy of the POD compared with EPF in patients with life-threatening pelvic fra...

متن کامل

Noninvasive reduction of open-book pelvic fractures by circumferential compression.

OBJECTIVES To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN Biomechanical investigation on human cadaveric specimens. SETTING Biomechanics laboratory. INTERVENTION Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created ...

متن کامل

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study.

BACKGROUND Pelvic circumferential compression devices are designed to stabilize the pelvic ring and reduce the volume of the pelvis following trauma. It is uncertain whether pelvic circumferential compression devices can be safely applied for all types of pelvic fractures because the effects of the devices on the reduction of fracture fragments are unknown. The aim of this study was to compare ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury

دوره 39 8  شماره 

صفحات  -

تاریخ انتشار 2008