CLINICAL INVESTIGATION Progressive Suppression of Motor Evoked Potentials During General Anesthesia
نویسنده
چکیده
Transcranial motor evoked potentials (MEPs) are useful for assessing the integrity of spinal cord motor tracts during major spine surgery. Anesthetic agents depress the amplitude of MEPs in a dose-dependant fashion. Anecdotal reports suggest that MEP responses degrade or ‘‘fade’’ over the duration of a surgery, despite unchanged anesthetic levels or other physiologic variables. This phenomenon has not been systematically analyzed. We performed a retrospective study of 418 patients who underwent spine surgery at UCSF using intraoperative MEP monitoring. We excluded patients who experienced variations in physiologic parameters that might affect MEP signals and those who developed new neurologic deficits. We identified 46 neurologically intact patients and 16 myelopathic patients who had surgery performed using a constant desflurane/N2O /narcotic or desflurane/propofol/narcotic anesthetic regimen. The minimum voltage threshold needed to produce an MEP response of at least 50 mV in amplitude was recorded at the beginning (‘‘baseline’’) and end of surgery. The voltage threshold was higher at the end of the case than at baseline for each patient, regardless of anesthetic regimen. In normal patients, the rate of rise of the threshold was similar for those receiving propofol (11.46 6.9 V/hr) or N2O (9.7 6 5.9 V/hr) (P = not significant). Myelopathic patients demonstrated a larger rate of rise in voltage threshold, 23.4 6 12.2 V/hr, versus normal subjects (P , 0.01). The rate of rise of voltage threshold is inversely proportional to anesthetic duration. Prolonged exposure to anesthetic agents necessitates higher stimulating thresholds to elicit MEP responses, separate from the dose-dependant depressant effect. This retrospective study is limited and cannot explain the mechanism for this observed fade in signals. Recognition of anesthetic fade is essential when interpreting changes to the MEP response to avoid false-
منابع مشابه
Attenuation of Motor Evoked Potentials Following Prone Positioning
Background and Importance Of outmost importance for the success of neurosurgical operations is proper patient positioning. This is particularly the case for operations conducted in the prone position, which is associated with several potential complications. Case presentation Here we report the case of a 52 years old male patient who underwent endoscopic discectomy for an L5-S1 herniated dis...
متن کاملReliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal
Introduction: Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical context depends on their intra-and inter-session reliability. This study aimed to evaluate if removal ...
متن کاملInter-pulse Interval Affects the Size of Single-pulse TMS-induced Motor Evoked Potentials: a Reliability Study
Introduction: Measuring the size of motor evoked potentials (MEPs) induced by transcranial magnetic stimulation (TMS) is an investigational technique to show the level of corticospinal excitability however, some of the fundamental methodological aspects of TMS (such as the effects of inter-pulse intervals (IPI) on MEP size) are not fully understood, this issue raises concerns about the re...
متن کاملSomatosensory Evoked Potentials suppression due to remifentanil during spinal operations; a prospective clinical study
BACKGROUND Somatosensory evoked potentials (SSEP) are being used for the investigation and monitoring of the integrity of neural pathways during surgical procedures. Intraoperative neurophysiologic monitoring is affected by the type of anesthetic agents. Remifentanil is supposed to produce minimal or no changes in SSEP amplitude and latency. This study aims to investigate whether high doses of ...
متن کاملMotor and somatosensory evoked potentials are well maintained in patients given dexmedetomidine during spine surgery.
BACKGROUND Many commonly used anesthetic agents produce a dose-dependent amplitude reduction and latency prolongation of evoked responses, which may impair diagnosis of intraoperative spinal cord injury. Dexmedetomidine is increasingly used as an adjunct for general anesthesia. Therefore, the authors tested the hypothesis that dexmedetomidine does not have a clinically important effect on somat...