Validity and reliability of Kinect skeleton for measuring shoulder joint angles: a feasibility study.

نویسندگان

  • M E Huber
  • A L Seitz
  • M Leeser
  • D Sternad
چکیده

OBJECTIVE To test the reliability and validity of shoulder joint angle measurements from the Microsoft Kinect™ for virtual rehabilitation. DESIGN Test-retest reliability and concurrent validity, feasibility study. SETTING Motion analysis laboratory. PARTICIPANTS A convenience sample of 10 healthy adults. METHODS Shoulder joint angle was assessed in four static poses, two trials for each pose, using: (1) the Kinect; (2) a three-dimensional motion analysis system; and (3) a clinical goniometer. All poses were captured with the Kinect from the frontal view. The two poses of shoulder flexion were also captured with the Kinect from the sagittal view. MAIN OUTCOME MEASURES Absolute and relative test-retest reliability of the Kinect for the measurement of shoulder angle was determined in each pose with intraclass correlation coefficients (ICCs), standard error of the measure and minimal detectable change. The 95% limits of agreement (LOA) between the Kinect and the standard methods for measuring shoulder angle were computed to determine concurrent validity. RESULTS While the Kinect provided to be highly reliable (ICC 0.76-0.98) for measuring shoulder angle from the frontal view, the 95% LOA between the Kinect and the two measurement standards were greater than ±5° in all poses for both views. CONCLUSIONS Before the Kinect is used to measure movements for virtual rehabilitation applications, it is imperative to understand its limitations in precision and accuracy for the measurement of specific joint motions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability and validity of the Microsoft Kinect for assessment of manual wheelchair propulsion.

Concurrent validity and test-retest reliability of the Microsoft Kinect in quantification of manual wheelchair propulsion were examined. Data were collected from five manual wheelchair users on a roller system. Three Kinect sensors were used to assess test-retest reliability with a still pose. Three systems were used to assess concurrent validity of the Kinect to measure propulsion kinematics (...

متن کامل

Psychometric Properties of the Persian Version of the Simple Shoulder Test (SST) Questionnaire

  Background: To validate the Persian version of the simple shoulder test in patients with shoulder joint problems.   Methods: Following Beaton`s guideline, translation and back translation was conducted. We reached to a consensus on the Persian version of SST. To test the face validity in a pilot study, the Persian SST was administered to 20 individuals with shoulder joint conditions. We enrol...

متن کامل

Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

BACKGROUND The aims of this study were to evaluate the construct validity (known group), concurrent validity (criterion based) and test-retest (intra-rater) reliability of manual goniometers to measure passive hip range of motion (ROM) in femoroacetabular impingement patients and healthy controls. METHODS Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simu...

متن کامل

Markerless Knee Joint Position Measurement Using Depth Data during Stair Walking

Climbing and descending stairs are demanding daily activities, and the monitoring of them may reveal the presence of musculoskeletal diseases at an early stage. A markerless system is needed to monitor such stair walking activity without mentally or physically disturbing the subject. Microsoft Kinect v2 has been used for gait monitoring, as it provides a markerless skeleton tracking function. H...

متن کامل

Assessing posterior shoulder contracture: the reliability and validity of measuring glenohumeral joint horizontal adduction.

CONTEXT Increased contracture of the dominant posterior shoulder in throwing athletes has been associated with the development of altered shoulder rotational motion as well as several shoulder conditions. Clinicians must be able to accurately and reliably measure posterior shoulder contractures during the evaluation of such athletes in order to provide appropriate treatment. OBJECTIVE To eval...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiotherapy

دوره 101 4  شماره 

صفحات  -

تاریخ انتشار 2015