Novel x-ray attenuation mechanism: role of interatomic distance.
نویسندگان
چکیده
Little progress has been made over the last 30 years for improving attenuation by x-ray contrast agents, in part because the mechanisms of x-ray attenuation are thought to be well understood. We hypothesized that x-ray absorbance can be modulated by altering the interatomic spacing between K-edge attenuating atoms. Iodomethane, diiodomethane, 2,6-diiodo-4-nitroanaline, and diiodobenzene isomers were dissolved in DMSO and imaged with an OEC Compact 7600 fluoroscope. At a tube voltage of 42 kVp, absorbance of equimolar diiodomethane (150 mM) was significantly (p<0.01) greater than iodomethane (150 mM) by 45%. Interestingly, 150 mM diiodomethane absorbance was significantly greater than 300 mM iodomethane (by 5%, p<0.01) despite equal amounts of iodine in both solutions. 1,3-diiodobenzene absorbance was significantly greater than 1,2- and 1,4-diiodobenzene (p<0.01). However, 2,6-diiodo-4-nitroanaline absorbance was similar to 1,3-diiodobenzene. When a linear model was fit for absorbance as a function of density and harmonic error (the fractional remainder of the inter-iodine distance and the K-shell ionizing wavelength) at different beam energies, a significant overall fit was obtained for both unfiltered and hardened beams (p<0.01). While the slope of absorbance as a function of harmonic error was significant for all conditions (p<0.01), the slope with respect to density was significant only when the beam was unfiltered (p<0.05). Also harmonic error, but not density, displayed significant energy-dependent effects on absorbance (p <0.01). These data suggest that harmonic error is a strong determinant of absorbance, particularly when the beam energy is concentrated near the iodine K-edge and is likely a descriptor of K-characteristic photon interactions. Therefore, x-ray absorbance may be modulated by the distance between covalently linked x-ray K-edge attenuating atoms. This finding has important implications for increasing contrast agent absorbance as well as for designing molecular transducers capable of modulating K-edge attenuating atomic distances and thereby x-ray absorbance.
منابع مشابه
Introducing a novel Polyvinyl chloride/Tungsten composites for shielding against gamma and X-ray radiations
Introduction: This study introduces a novel polyvinyl chloride (PVC)/tungsten composites with characterization of their shielding properties by employing different techniques. Methods: The PVC/tungsten composites were produced by employing various weight fractions of tungsten micro-particles including 0, 20, and 40 % wt via melt blending method. In the next st...
متن کاملEvaluation of effect of gold nanorods and spherical gold nanoparticles of different sizes on X-ray attenuation in computed tomography
Introduction: To date, gold nanoparticles (GNPs) have been demonstrated to have great potential as contrast agent for CT imaging and therapeutics. This study was designed to evaluate any effect on X-ray attenuation that might result from using GNPs with a variety of size, surface chemistries and shapes. Materials and Methods: Spherical GNPs and gold nanorod...
متن کاملDesign of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code
Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...
متن کاملApplication of characteristic X-rays to measure linear attenuation coefficient of nano-composites used in shielding
Using of X-rays in different industries and especially in medical application is increasing. In this regard, designing of light and efficient protective material based on polymeric nanocomposites and precise study of the effect of adding nanoparticles with different sizes on the X-ray attenuation is necessary. In this study the epoxy nanocomposites with different percentages of copper oxide nan...
متن کاملLocal atomic structure and the valence band structure of the rhombic-triacontahedral quasicrystal, its 1/1 approximant, and the Mackay-icosahedral quasicrystal in the Al-Mg-Pd alloy system
The rhombic-triacontahedral-type quasicrystal ~RT-QC!, its (1/1, 1/1, 1/1) approximant (RT-1/1) and the Mackay-icosahedral-type quasicrystal ~MI-QC! can be formed in the Al-Mg-Pd system. The radial distribution function RDF(r) spectra of the three compounds is derived from neutron diffraction experiments. Powdered x-ray diffraction Rietveld refinement is also carried out to determine the atomic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 35 10 شماره
صفحات -
تاریخ انتشار 2008