Volumetric intensity-modulated Arc (RapidArc) therapy for primary hepatocellular carcinoma: comparison with intensity-modulated radiotherapy and 3-D conformal radiotherapy
نویسندگان
چکیده
BACKGROUND To compare the RapidArc plan for primary hepatocellular carcinoma (HCC) with 3-D conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) plans using dosimetric analysis. METHODS Nine patients with unresectable HCC were enrolled in this study. Dosimetric values for RapidArc, IMRT, and 3DCRT were calculated for total doses of 45~50.4 Gy using 1.8 Gy/day. The parameters included the conformal index (CI), homogeneity index (HI), and hot spot (V₁₀₇%) for the planned target volume (PTV) as well as the monitor units (MUs) for plan efficiency, the mean dose (Dmean) for the organs at risk (OAR) and the maximal dose at 1% volume (D1%) for the spinal cord. The percentage of the normal liver volume receiving ≥ 40, > 30, > 20, and > 10 Gy (V₄₀ Gy, V₃₀ Gy, V₂₀ Gy, and V₁₀ Gy) and the normal tissue complication probability (NTCP) were also evaluated to determine liver toxicity. RESULTS All three methods achieved comparable homogeneity for the PTV. RapidArc achieved significantly better CI and V107% values than IMRT or 3DCRT (p < 0.05). The MUs were significantly lower for RapidArc (323.8 ± 60.7) and 3DCRT (322.3 ± 28.6) than for IMRT (1165.4 ± 170.7) (p < 0.001). IMRT achieved a significantly lower Dmean of the normal liver than did 3DCRT or RapidArc (p = 0.001). 3DCRT had higher V₄₀Gy and V₃₀ Gy values for the normal liver than did RapidArc or IMRT. Although the V10 Gy to the normal liver was higher with RapidArc (75.8 ± 13.1%) than with 3DCRT or IMRT (60.5 ± 10.2% and 57.2 ± 10.0%, respectively; p < 0.01), the NTCP did not differ significantly between RapidArc (4.38 ± 2.69) and IMRT (3.98 ± 3.00) and both were better than 3DCRT (7.57 ± 4.36) (p = 0.02). CONCLUSIONS RapidArc provided favorable tumor coverage compared with IMRT or 3DCRT, but RapidArc is not superior to IMRT in terms of liver protection. Further studies are needed to establish treatment outcome differences between the three approaches.
منابع مشابه
Comparison of RapidArc and Static Gantry Intensity-modulated Radiotherapy for Nasopharyngeal Carcinoma
Objective: RapidArc (Varian Medical Systems, Palo Alto, CA) is a new volumetric-modulated arc radiotherapy technique with continuous modulation of gantry speed, dose rate, and multileaf collimator shape. Taking advantages of dose painting capabilities along with rotational delivery, RapidArc has shown promise in the treatment of a wide range of tumours, including intracranial, head and neck, pr...
متن کاملA comparison of liver protection among 3-D conformal radiotherapy, intensity-modulated radiotherapy and RapidArc for hepatocellular carcinoma
PURPOSE The analysis was designed to compare dosimetric parameters among 3-D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and RapidArc (RA) to identify which can achieve the lowest risk of radiation-induced liver disease (RILD) for hepatocellular carcinoma (HCC). METHODS Twenty patients with HCC were enrolled in this study. Dosimetric values for 3DCRT, IMRT, and RA ...
متن کاملDosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer
PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, nonc...
متن کاملRadiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma
Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...
متن کاملIntensity-modulated radiotherapy for hepatocellular carcinoma: dosimetric and clinical results
Since the introduction of 3-dimensional conformal radiotherapy (3DCRT), new radiotherapy techniques have expanded the indication of radiotherapy for the treatment of hepatocellular carcinoma (HCC), from the hitherto palliative to a now curative-intent purpose. Intensity-modulated radiotherapy (IMRT), currently the most advanced radiotherapy technique, is considered an attractive option for the ...