Midterm Experience of Ipsilateral Axillary-Axillary Arteriovenous Loop Graft as Tertiary Access for Haemodialysis

نویسندگان

  • J. P. Hunter
  • M. L. Nicholson
چکیده

Objectives. To present a series of ipsilateral axillary artery to axillary vein loop arm grafts as an alternative vascular access procedure for haemodialysis in patients with difficult access. Design. Retrospective case series. Methods. Patients who underwent an axillary loop arteriovenous graft from September 2009 to September 2012 were included. Preoperative venous imaging to exclude central venous stenosis and to image arm/axillary veins was performed. A cuffed PTFE graft was anastomosed to the distal axillary artery and axillary vein and looped on the arm. Results. 25 procedures were performed on 22 patients. Median age was 51 years, with 9 males and 13 females. Median number of previous access procedures was 3 (range 0-7). Median followup was 16.4 months (range 1-35). At 3 months and 1 year, the primary and secondary patency rates were 70% and 72% and 36% and 37%, respectively. There were 11 radiological interventions in 6 grafts including 5 angioplasties and 6 thrombectomies. There were 19 surgical procedures in 10 grafts, including thrombectomy, revision, repair for bleeding, and excision. Conclusions. Our series demonstrates that the axillary loop arm graft yields acceptable early patency rates in a complex group of patients but to maintain graft patency required high rates of surgical and radiological intervention, in particular graft thrombectomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extra-anatomical veno-venous surgical bypass for central vein occlusion in patients with ipsilateral arterio-venous fistula (AVF) for haemodialysis - A single centre experience.

OBJECTIVE Central vein occlusion is a common complication related to central vein catheter insertion for haemodialysis which can be unmasked by an ipsilateral fistula creation, leading to a dysfunctional arteriovenous fistula (AVF). We describe an extra-anatomical venous bypass surgical procedure performed to maintain vascular access and reduce the symptoms of swelling of the ipsilateral upper ...

متن کامل

Percutaneous Intervention in Axillary Loop-Configured Arteriovenous Grafts for Chronic Hemodialysis Patients

OBJECTIVE The purpose of this study was to evaluate the fistulographic features of malfunctioning axillary loop-configured arteriovenous grafts and the efficacy of percutaneous interventions in failed axillary loop-configured arteriovenous grafts. MATERIALS AND METHODS Ten patients with axillary loop-configured arteriovenous grafts were referred for evaluation of graft patency or upper arm sw...

متن کامل

Emergency Hybrid Repair of an Infected Pseudo-aneurysm of an Axillary Dialysis Necklace Graft

Synthetic grafts are placed for haemodialysis access in patients when other access options have been exhausted [1]. These synthetic grafts may act as a nidus for infection and ideal management is by excision and vessel repair [2]. Surgical repair may be challenging due to friable vessels secondary to the infection, and conventional practice avoids stent placement in an infected field. We report...

متن کامل

Axillary loop grafts for hemodialysis access: midterm results from a single-center study.

PURPOSE This study reports our midterm results with arteriovenous axillary loop grafts (AVALG) and evaluates their role in construction of vascular access for patients on chronic hemodialysis. METHODS The clinical data of 27 patients who underwent construction of an AVALG for hemodialysis access at our institution between July 2002 and December 2006 were analyzed retrospectively. Outcome meas...

متن کامل

Bovine ureter graft for haemodialysis access surgery.

Bovine ureter SynerGraft (SG) (CryoLife, Inc.) has been recently introduced into haemodialysis access surgery. It is a non-glutaraldehyde fixed acellular collagen and elastin matrix conduit that may withstand arterial pressures. There has only been one published report in humans with this graft for vascular access, except for a canine model which Matsuura et al. reported [1]. In this study, we ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014