Intra- and inter-rater reliability for analysis of hyoid displacement measured with sonography.

نویسندگان

  • Phoebe R Macrae
  • Sebastian H Doeltgen
  • Richard D Jones
  • Maggie-Lee Huckabee
چکیده

PURPOSE Anterior hyoid displacement is essential for efficient swallowing and is usually investigated with videofluoroscopy. Ultrasound offers a less expensive and noninvasive method of investigation. The present study investigated the viability of a novel method of quantifying hyoid displacement from sonograms using an anatomic reference point, through an evaluation of inter- and intra-rater reliability. METHODS Three raters reviewed the sonographic video sweeps of five discrete swallows from each of five participants for inter-rater reliability. The primary investigator measured each swallow on two occasions for intra-rater reliability. Electronic calipers were used to measure distances from a "rest" frame prior to the swallow of interest and a "maximal displacement" frame, at which the hyoid bone was at maximal anterior displacement during each swallow. RESULTS Single-measure intraclass correlation coefficient was high for inter-rater agreement at 0.86 for rest measures and 0.86 for maximal displacement. Intra-rater reliability was even higher at 0.95 for rest and 0.98 for maximal displacement. CONCLUSIONS These preliminary results suggest that by using a novel analysis approach involving an anatomic reference point, raters can achieve high agreement on measurement of position of hyoid at maximal displacement relative to rest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Spasticity Using the Ashworth Scale with Intermediate Scores (ASIS)

Objectives: The main purpose of this research was to study and contribute to an accurate test of spastic limb. The intra, inter rater reliability of the test was examined. Methods: The present study was carried out in two parts In the first part of the study, the modified Ashworth Scale with Intermediate Scores (ASIS) was studied. During the second part of the study the intra, inter rater re...

متن کامل

STAMPS: development and verification of swallowing kinematic analysis software

BACKGROUND Swallowing impairment is a common complication in various geriatric and neurodegenerative diseases. Swallowing kinematic analysis is essential to quantitatively evaluate the swallowing motion of the oropharyngeal structures. This study aims to develop a novel swallowing kinematic analysis software, called spatio-temporal analyzer for motion and physiologic study (STAMPS), and verify ...

متن کامل

Functional Movement Screen in Elite Boy Basketball Players: A Reliability Study

Purpose: To investigate the reliability of Functional Movement Screen (FMS) in basketball players. A few studies have compared the reliability of FMS between raters with different experience in athletes. The purpose of this study was to compare the FMS scoring between the beginners and expert raters using video records.  Methods: This is a cross-sectional study. The study subjects compris...

متن کامل

Reliability of Body Landmarks Analyzer for Measuring the Quadriceps Angle

Genovarum and Genovalgum are the most common postural deformities of the knee joint. A quadriceps angle is used to measure these anomalies. Methods of measuring this angle are divided into two categories: invasive and non-invasive. The purpose of the present research was to study the inter/intra rater reliability of the non-invasive Body Landmarks Analyzer method for measuring of the quadriceps...

متن کامل

Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy

Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical ultrasound : JCU

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2012