Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer.

نویسندگان

  • Søren Haack
  • Søren Kynde Nielsen
  • Jacob Christian Lindegaard
  • John Gelineck
  • Kari Tanderup
چکیده

BACKGROUND AND PURPOSE To elaborate a method for applicator reconstruction for MRI-based brachytherapy for cervical cancer. MATERIALS AND METHODS Custom-made plastic catheters with a copper sulphate solution were made for insertion in the source channels of MR-CT compatible applicators: plastic and titanium tandem ring applicators, and titanium needles. The applicators were CT and MR scanned in a phantom for accurate 3D assessment of applicator visibility and geometry. A reconstruction method was developed and evaluated in 19 patient MR examinations with ring applicator (plastic: 14, titanium: 5). MR applicator reconstruction uncertainties related to inter-observer variation were evaluated. RESULTS The catheters were visible in the plastic applicator on T1-weighted images in phantom and in 14/14 clinical applications. On T2-weighted images, the catheters appeared weaker but still visible in phantom and in 13/14 MR clinical applications. In the titanium applicator, the catheters could not be separated from the artifacts from the applicator itself. However, these artifacts could be used to localize both titanium ring applicator (5/5 clinical applications) and needles (6/6 clinical applications). Standard deviations of inter-observer differences were below 2 mm in all directions. CONCLUSION 3D applicator reconstruction based on MR imaging could be performed for plastic and titanium applicators. Plastic applicators proved well to be suited for MRI-based reconstruction. For improved practicability of titanium applicator reconstruction, development of MR applicator markers is essential. Reconstruction of titanium applicator and needles at 1.5 T MR requires geometric evaluations in phantoms before using the applicator in patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A questionnaire-based survey on 3D image-guided brachytherapy for cervical cancer in Japan: advances and obstacles

The purpose of this study is to survey the current patterns of practice, and barriers to implementation, of 3D image-guided brachytherapy (3D-IGBT) for cervical cancer in Japan. A 30-item questionnaire was sent to 171 Japanese facilities where high-dose-rate brachytherapy devices were available in 2012. In total, 135 responses were returned for analysis. Fifty-one facilities had acquired some s...

متن کامل

The use of trans-applicator intracavitary ultrasonography in brachytherapy for cervical cancer: phantom study of a novel approach to 3D image-guided brachytherapy

PURPOSE To assess the feasibility of applying trans-applicator intracavitary ultrasonography to image-guided brachytherapy for cervical cancer. MATERIAL AND METHODS For this experiment, a phantom was created and included a polyethylene tube, intended to simulate a tandem applicator, which was inserted into chicken meat and embedded in agar, along with magnetic resonance imaging (MRI)-compatib...

متن کامل

Optimal single 3T MR imaging sequence for HDR brachytherapy of cervical cancer

PURPOSE The superior image quality of 3 tesla (3T) magnetic resonance (MR) imaging in cervical cancer offers the potential to use a single image set for brachytherapy. This study aimed to determine a suitable single sequence for contouring tumour and organs at risk, applicator reconstruction, and treatment planning. MATERIAL AND METHODS A 3T (Skyra, Siemens Healthcare AG, Germany) MR imaging ...

متن کامل

Commissioning of a 3D image‐based treatment planning system for high‐dose‐rate brachytherapy of cervical cancer

The objective of this work is to present commissioning procedures to clinically implement a three-dimensional (3D), image-based, treatment-planning system (TPS) for high-dose-rate (HDR) brachytherapy (BT) for gynecological (GYN) cancer. The physical dimensions of the GYN applicators and their values in the virtual applicator library were varied by 0.4 mm of their nominal values. Reconstruction ...

متن کامل

MRI assisted cervix cancer brachytherapy pre-planning, based on insertion of the applicator in para-cervical anaesthesia: preliminary results of a prospective study

PURPOSE To report on preliminary results of a prospective study on MRI-assisted cervix cancer brachytherapy pre-planning. MATERIAL AND METHODS In six locally advanced cervix cancer patients, five days before the first brachytherapy fraction, tandem & ring applicator was inserted under para-cervical anaesthesia, MRI performed and applicator removed. Procedure-time and patient-tolerability were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 91 2  شماره 

صفحات  -

تاریخ انتشار 2009