International Nosocomial Infection Control Consortium (INICC) report, data summary for 2003-2008, issued June 2009.

نویسندگان

  • Victor D Rosenthal
  • Dennis G Maki
  • Silom Jamulitrat
  • Eduardo A Medeiros
  • Subhash Kumar Todi
  • David Yepes Gomez
  • Hakan Leblebicioglu
  • Ilham Abu Khader
  • María Guadalupe Miranda Novales
  • Regina Berba
  • Fernando Martín Ramírez Wong
  • Amina Barkat
  • Osiel Requejo Pino
  • Lourdes Dueñas
  • Zan Mitrev
  • Hu Bijie
  • Vaidotas Gurskis
  • S S Kanj
  • Trudell Mapp
  • Rosalía Fernández Hidalgo
  • Nejla Ben Jaballah
  • Lul Raka
  • Achilleas Gikas
  • Altaf Ahmed
  • Le Thi Anh Thu
  • María Eugenia Guzmán Siritt
چکیده

We report the results of the International Infection Control Consortium (INICC) surveillance study from January 2003 through December 2008 in 173 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study, using Centers for Disease Control and Prevention (CDC) US National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infection, we collected prospective data from 155,358 patients hospitalized in the consortium's hospital ICUs for an aggregate of 923,624 days. Although device utilization in the developing countries' ICUs was remarkably similar to that reported from US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were markedly higher in the ICUs of the INICC hospitals: the pooled rate of central venous catheter (CVC)-associated bloodstream infections (BSI) in the INICC ICUs, 7.6 per 1000 CVC-days, is nearly 3-fold higher than the 2.0 per 1000 CVC-days reported from comparable US ICUs, and the overall rate of ventilator-associated pneumonia (VAP) was also far higher, 13.6 versus 3.3 per 1000 ventilator-days, respectively, as was the rate of catheter-associated urinary tract infection (CAUTI), 6.3 versus 3.3 per 1000 catheter-days, respectively. Most strikingly, the frequencies of resistance of Staphylococcus aureus isolates to methicillin (MRSA) (84.1% vs 56.8%, respectively), Klebsiella pneumoniae to ceftazidime or ceftriaxone (76.1% vs 27.1%, respectively), Acinetobacter baumannii to imipenem (46.3% vs 29.2%, respectively), and Pseudomonas aeruginosa to piperacillin (78.0% vs 20.2%, respectively) were also far higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 23.6% (CVC-associated bloodstream infections) to 29.3% (VAP).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

International Nosocomial Infection Control Consortium report, data summary for 2002-2007, issued January 2008.

We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from 2002 through 2007 in 98 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study, using Centers for Disease Control and Prevention (CDC) National Nosocomial Infections Surveillance System (NNIS) definitions for device-associated health care-ass...

متن کامل

International Nosocomial Infection Control Consortium (INICC) report, data summary of 36 countries, for 2004-2009.

The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; forme...

متن کامل

The International Nosocomial Infection Control Consortium (INICC): goals and objectives, description of surveillance methods, and operational activities.

We have shown that intensive care units (ICUs) in countries with limited resources have rates of device-associated health care-associated infection (HAI), including central line-related bloodstream infection (CLAB), ventilator-associated pneumonia (VAP), and catheter-associated urinary tract infection (CAUTI), 3 to 5 times higher than rates reported from North American, Western European, and Au...

متن کامل

Device-associated nosocomial infections in limited-resources countries: findings of the International Nosocomial Infection Control Consortium (INICC).

NEED The rates of health care-associated infections (HAIs) and bacterial resistance in developing countries are 3 to 5 times higher than international standards. HAIs increase length of stay (10 days), costs (US $5000 to US $12,000), and mortality (by a factor of 2 to 3). ORGANIZATION The International Nosocomial Infection Control Consortium (INICC), founded in 1998, is the only source of agg...

متن کامل

Surgical site infections, International Nosocomial Infection Control Consortium (INICC) report, data summary of 30 countries, 2005-2010.

OBJECTIVE  To report the results of a surveillance study on surgical site infections (SSIs) conducted by the International Nosocomial Infection Control Consortium (INICC). DESIGN  Cohort prospective multinational multicenter surveillance study. SETTING  Eighty-two hospitals of 66 cities in 30 countries (Argentina, Brazil, Colombia, Cuba, Dominican Republic, Egypt, Greece, India, Kosovo, Leb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of infection control

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2010