Assessment of the agreement between photoplethysmographic and arterial waveform respiratory variation in patients undergoing spine surgery.

نویسندگان

  • Robert H Thiele
  • Douglas A Colquhoun
  • Katherine T Forkin
  • Marcel E Durieux
چکیده

Respiratory variation in the arterial blood pressure and photoplethysmographic (PPG) waveforms have both been shown to predict the haemodynamic response to volume administration. Whether or not the two can be considered interchangeable is controversial. Twenty-three patients undergoing spine surgery received both a 20 gauge intra-arterial catheter and a Masimo adult adhesive SpHb sensor connected to a Radical-7 monitor. Pulse pressure variation (PPV) was calculated off-line at 1-min intervals. Pleth Variability Index (PVI) and Perfusion Index data were recorded. After exclusion of outliers, agreement between PPV and PVI was assessed using a repeated measures Bland-Altman approach. Concordance between changes in PPV and PVI was assessed using a four-quadrant plot with a 20% zone of exclusion. In total, 6549 min of data were collected. Repeated measures Bland-Altman analysis identified a bias of 2.2% and 95% confidence intervals of ±15.3% (limits of agreement -13.1 and +17.6%). The concordance rate between changes in PPV and changes in PVI was 51%. The agreement between respiratory variation in the arterial blood pressure and PPG waveforms is poor and these two should not be considered interchangeable. Changes in PPV are unrelated to changes in PVI. The data, combined with recently published work from other authors, suggests that the low frequency oscillations in the PPG waveform are not related to the low frequency oscillation in the systemic arterial blood pressure tracing and may be related to changes in venous pressure, peripheral tone or other physiologic phenomena yet to be described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting factors of serum lactate in patients under general anesthesia with propofol during spine surgery

Introduction: Increased serum lactate is seen during surgery due to tissue hypoxia. There have been reports of propofol infusion syndrome due to long-term use of this drug, especially in intensive care patients. This study was conducted to evaluate the factors affecting serum lactate levels in patients under general anesthesia with propofol in spine surgery. Methods: In a cross-sectional study...

متن کامل

بررسی میزان خونریزی در اعمال جراحی فیوژن خلفی مهره های کمری با پیش داروی کلونیدین خوراک

Background: Blood loss in spine surgery is an important issue, even though it has been understudied compared to hip and knee arthroplasty surgery. In this study we have evaluated the effect of oral clonidine as premedication on blood loss in lumbar spine fusion surgery under propofol and remifentanil anesthesia.Materials and Methods: In this prospective double-blinded randomized clinical trial,...

متن کامل

Is the pleth variability index a surrogate for pulse pressure variation in a pediatric population undergoing spine fusion?

OBJECTIVE To compare simultaneous measurements of pulse pressure variation (PPV) and pleth variability index (PVI) in patients undergoing spinal fusion. AIMS To determine if PVI can be used as a surrogate for PPV and also the influence of the prone position on these measurements. BACKGROUND Spine fusion is an involved surgical procedure requiring attention to fluid administration. Dynamic i...

متن کامل

Effect of Instructional Videos on Postoperative Respiratory Function in Patients Undergoing Off-Pump Open Heart Surgery

Background: Respiratory function in patients undergoing open heart surgery is disrupted after surgery.  Patient education on managing complications can reduce occurrence or severity of them. A variety of educational tools has been introduced, but there are controversies about the most appropriate tools. Aim: Determine the effect of instructional videos on respiratory function of the patients af...

متن کامل

Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients

INTRODUCTION Respiratory variation in arterial pulse pressure is a reliable predictor of fluid responsiveness in mechanically ventilated patients with circulatory failure. The main limitation of this method is that it requires an invasive arterial catheter. Both arterial and pulse oximetry plethysmographic waveforms depend on stroke volume. We conducted a prospective study to evaluate the relat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical engineering & technology

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 2013