Dyssynchrony by speckle-tracking echocardiography and response to cardiac resynchronization therapy: results of the Speckle Tracking and Resynchronization (STAR) study
نویسندگان
چکیده
AIMS The Speckle Tracking and Resynchronization (STAR) study used a prospective multi-centre design to test the hypothesis that speckle-tracking echocardiography can predict response to cardiac resynchronization therapy (CRT). METHODS AND RESULTS We studied 132 consecutive CRT patients with class III and IV heart failure, ejection fraction (EF) < or =35%, and QRS > or =120 ms from three international centres. Baseline dyssynchrony was evaluated by four speckle tracking strain methods; radial, circumferential, transverse, and longitudinal (> or =130 ms opposing wall delay for each). Pre-specified outcome variables were EF response and three serious long-term events: death, transplant, or left ventricular assist device. Of 120 patients (91%) with baseline dyssynchrony data, both short-axis radial strain and transverse strain from apical views were associated with favourable EF response 7 +/- 4 months and long-term outcome over 3.5 years (P < 0.01). Radial strain had the highest sensitivity at 86% for predicting EF response with a specificity of 67%. Serious long-term unfavourable events occurred in 20 patients after CRT, and happened three times more frequently in those who lacked baseline radial or transverse dyssynchrony than in patients with dyssynchrony (P < 0.01). Patients who lacked both radial and transverse dyssynchrony had unfavourable clinical events occur in 53%, in contrast to events occurring in 12% if baseline dyssynchrony was present (P < 0.01). Circumferential and longitudinal strains predicted response when dyssynchrony was detected, but failed to identify dyssynchrony in one-third of patients who responded to CRT. CONCLUSION Dyssynchrony by speckle-tracking echocardiography using radial and transverse strains is associated with EF response and long-term outcome following CRT.
منابع مشابه
Comparison of CMR DENSE strain imaging and 2D speckle tracking echocardiography for cardiac resynchronization therapy (CRT) response
Background Considering that nonresponse rates to cardiac resynchronization therapy (CRT) are typically 35-50%, assessment of the cardiac substrate for CRT with cardiac imaging could be very helpful for many patients with heart failure referred for this therapy. We have previously shown that CMR assessment of dyssynchrony using displacement encoding with stimulated echoes (DENSE) is strongly ass...
متن کاملStrain dyssynchrony index determined by three-dimensional speckle area tracking can predict response to cardiac resynchronization therapy
BACKGROUND We have previously reported strain dyssynchrony index assessed by two-dimensional speckle tracking strain, and a marker of both dyssynchrony and residual myocardial contractility, can predict response to cardiac resynchronization therapy (CRT). A newly developed three-dimensional (3-D) speckle tracking system can quantify endocardial area change ratio (area strain), which coupled wit...
متن کاملNovel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy.
BACKGROUND Mechanical dyssynchrony is a potential means to predict response to cardiac resynchronization therapy (CRT). We hypothesized that novel echocardiographic image speckle tracking can quantify dyssynchrony and predict response to CRT. METHODS AND RESULTS Seventy-four subjects were studied: 64 heart failure patients undergoing CRT (aged 64+/-12 years, ejection fraction 26+/-6%, QRS dur...
متن کاملFeature tracking measurement of dyssynchrony from cardiovascular magnetic resonance cine acquisitions: comparison with echocardiographic speckle tracking
BACKGROUND Analysis of left ventricular (LV) mechanical dyssynchrony may provide incremental prognostic information regarding cardiac resynchronization therapy (CRT) response in addition to QRS width alone. Our objective was to quantify LV dyssynchrony using feature tracking post processing of routine cardiovascular magnetic resonance (CMR) cine acquisitions (FT-CMR) in comparison to speckle tr...
متن کاملSpeckle tracking echocardiography: clinical applications in cardiac resynchronization therapy.
Cardiac resynchronization therapy (CRT) is a proven therapy for selected patients with heart failure, it has been shown to improve symptoms and left ventricular (LV) function and prolong survival. Despite proven benefit of CRT, a significant proportion of patients fail to respond to CRT. Multiple factors contribute to the non-response such as patient selection and device implantation including ...
متن کامل