Submicroliter electrochemistry and spectroelectrochemistry using standard electrodes and a polymer electrolyte salt bridge.

نویسندگان

  • Paul A Flowers
  • David A Blake
چکیده

The development of spectroscopic and electrochemical devices that can accommodate very small samples is of considerable importance to many areas of science and technology. We report here on the design and characteristics of a simple apparatus for the electrochemical and spectroelectrochemical analysis of submicroliter aqueous samples. The device is easily assembled from common laboratory materials and equipment, utilizing a bifurcated fiber-optic probe, standard disk electrodes of millimeter dimensions, and a polymer electrolyte film salt bridge to enable the analysis of nanoliter-scale sample volumes in a thin-layer configuration. Excellent performance has been demonstrated via measurements on aqueous ferricyanide solutions using sample volumes as low as 20 nL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-chip microelectrodes for electrochemistry with moveable PPy bilayer actuators as working electrodes

We present electrochemical microactuators which have all the electrodes necessary for the actuation -the working, counter, and reference electrodes -onchip. This is a first step towards an all-polymer system, i.e. a system that does not require a liquid electrolyte. The microactuators' performance was as good as when standard, off-chip counter and reference electrodes were used. Specifically, t...

متن کامل

The Electrochemistry of Gases : New Sensing Opportunities

Electrochemistry on gases originated in 1839 with Grove's "gaseous voltaic battery". Over 90 years later, Bacon built a demonstration fuel cell consisting of porous nickel electrodes. He is credited with creating a stable three phase reaction zone of electrode, gas, and electrolyte. Today's fuel cell electrodes are far more sophisticated and lend themselves to other important electrochemical pr...

متن کامل

Development of Carbon Paste Electrode/EDTA/Polymer Sensor for Heavy Metals Detection

The method used to immobilize the polymer on the Disodium ethylenediamine tetraacetate (EDTA) modified carbon paste electrode (CPE/EDTA) has proved its effectiveness for the detection and chelation of heavy metals in aqueous solution. Its complex formation with Pb(II) was examined by square wave voltammetry and cyclic voltammetry. CPE/EDTA electrodes are predisposed to the phenomenon of dissolu...

متن کامل

In Situ FT-IR/ATR Spectroelectrochemistry of Prussian Blue in the Solid State

Interfacial oxidation and reduction of Prussian Blue (PB), KFe[Fe(CN)6]‚nH2O (n ≈ 10), powder were probed in situ with Fourier transform infrared attenuated total reflection (FT-IR/ATR) spectroscopy. The combination of electrochemistry in the absence of liquid electrolyte with internal reflectance FT-IR spectroscopy was accomplished using a simple two-electrode sandwich-type cell in which a cry...

متن کامل

Mechanistic studies of pyridinium electrochemistry: alternative chemical pathways in the presence of CO2.

Protonated heterocyclic amines, such as pyridinium, have been utilized as catalysts in the electrocatalytic reduction of carbon dioxide. While these represent a new and exciting class of electrocatalysts, the details of the mechanism and faradaic processes occurring in solution are unclear. We report a series of cyclic voltammetry experiments involving Pt, Ag, Au, and Cu electrodes, under both ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 85 6  شماره 

صفحات  -

تاریخ انتشار 2013