Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

نویسندگان

  • Markus Windolf
  • Josh Schroeder
  • Ladina Fliri
  • Benno Dicht
  • Meir Liebergall
  • R Geoff Richards
چکیده

BACKGROUND The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure. METHODS The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. RESULTS A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (p < 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (p = 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). CONCLUSIONS In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures

Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...

متن کامل

Management of tibial non-:union: using reamed interlocking intra-medullary nailing

 Abstract  Background: Reamed interlocking intramedullary nailing of the tibia is a procedure  for the treatment of a non-infected tibial non:::union:::. The purpose of this clinical  study was to evaluate the outcome of this method as a treatment of tibial non:::union:::.  Methods: Twenty-nine patients with non:::union::: after initial therapy for tibial fracture  were retrospectively assessed...

متن کامل

A clinical outcome comparison of the conventional altered cast impression with a modification altered cast impression technique

A clinical outcome comparison of the conventional altered cast impression with a modification altered cast impression technique Dr. M. Farzin *- Dr. F. Bahrani ** - Dr. A. Zareie *** *Assistant Professor of Prosthodontics Dept., Faculty of Dentistry, Shiraz University of Medical Sciences. **Clinical Instructor of Prosthodontics Dept., Faculty of Dentistry, Shiraz University of Medical Sciences....

متن کامل

Finite element simulation of two-point incremental forming of free-form parts

Two-point incremental forming method is considered a modern technique for manufacturing shell parts. The presence of bottom punch during the process makes this technique far more complex than its conventional counterpart i.e. single-point incremental forming method. Thus, the numerical simulation of this method is an essential task, which leads to the reduction of trial/error costs, predicts th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012