Polystyrene Based Silver Selective Electrodes
نویسندگان
چکیده
Silver(I) selective sensors have been fabricated from polystyrene matrix membranes containing macrocycle, Me6(14) diene.2HClO4 as ionophore. Best performance was exhibited by the membrane having a composition macrocycle : Polystyrene in the ratio 15:1. This membrane worked well over a wide concentration range 5.0×10–1.0×10M of Ag with a near-Nernstian slope of 53.0 ± 1.0 mV per decade of Ag activity. The response time of the sensor is <15 s and the membrane can be used over a period of four months with good reproducibility. The proposed electrode works well in a wide pH range 2.5-9.0 and demonstrates good discriminating power over a number of mono-, di-, and trivalent cations. The sensor has also been used as an indicator electrode in the potentiometric titration of silver(II) ions against NaCl solution. The sensor can also be used in non-aqueous medium with no significant change in the value of slope or working concentration range for the estimation of Ag in solution having up to 25% (v/v) nonaqueous fraction.
منابع مشابه
Preparation and Characterization of Home-Made Silver Sulphide Based Chloride Selective Electrode
Introduction A number of works on cationic sensors have been reported in literatures [1] but less attention has been given towards the development of anionic sensors though there is a need for analysis of varieties of anions in different environmental, biomedical, industrial as well as chemical samples[2-3]. Anion sensors are simple, low cost, convenient, portable and provide quick response tow...
متن کاملAn Analysis of a Flexible Dry Surface Electrodes
Received Jan 5, 2018 Revised Mar 5, 2018 Accepted Mar 20, 2018 In the medical field, electrodes are commonly used either to retrieve signals or to conduct current. Most of the off-the-shelf surface electrodes are made from metal or rigid substrates. This paper presents a work on designing a new flexible dry electrodes using poly (3,4-ethylenedioxythiophene) polystyrene sulfonate and silver by m...
متن کاملPotentiometric determination of silver(I) by selective membrane electrode based on derivative of porphyrin.
The performance of silver metal complexes with meso-tetraphenylporphyrin ([H2T(4-CH3)]PP) as ionophores for ion-selective electrodes was studied. The electrode exhibited linear response with Nernstian slope of 59.2 +/- 1.0 mV per decade within the concentration range of 1.0 x 10(-7)-1.0 x 10(-1) M silver ions. The limit of detection as determined from the intersection of the extrapolated linear...
متن کاملPreparation of Low Cost Solid State Silver Sulfide Based Bromide Selective Electrodes
Preparation and performance of a cost effective silver sulfide based bromide selective membrane is described. A solid contact between membrane and body of the electrode was examined as an ion-selective electrode by determining S 2and Br ions by direct potentiometry. A linear response to bromide ion from 2 x 10 -5 to 10 -1 M with a slope of 57.3 mV per decade [Br ] is observed. The membrane has ...
متن کاملSilver ion recognition using potentiometric sensor based on recently synthesized isoquinoline-1,3-dione derivatives
The four derivatives of isoquinoline-1,3-dione based on β-lactum (I-IV), have been explored as neutral ionophores for preparing poly(vinylchloride) based polymeric membrane electrodes (PME) selective to silver(I) ions. The addition of sodium tetraphenylborate (NaTPB) and dioctylsebacate (DOS) as a plasticizer was found to improve the performance of ion selective electrodes. The best performance...
متن کامل