Amplitude of the ocular pneumoplethysmography waveform is correlated with cardiac output.

نویسندگان

  • T M Bosley
  • M S Cohen
  • W Gee
  • J Reed
  • R C Sergott
  • P J Savino
چکیده

BACKGROUND AND PURPOSE Ocular pulse amplitude, the amplitude of the ocular pneumoplethysmographic waveform, is altered in several ophthalmologic diseases that disturb ocular blood flow, implying that ocular pulse amplitude may provide an estimate of ocular blood flow. Because ocular blood flow currently cannot be quantified in humans, two experiments were undertaken to evaluate the association of ocular pulse amplitude with total body blood flow. METHODS In experiment 1, cardiac output was determined by cardiac catheterization in 181 patients who underwent OPG-Gee testing during the same hospitalization. In experiment 2, 110 instances of atrial arrhythmia captured on ocular pneumoplethysmographic tracings were evaluated for transient changes in heart rate (R-R ratio) associated with transient changes in ocular pulse amplitude (ocular pulse amplitude ratio). RESULTS In experiment 1, average ocular pulse amplitude in the two eyes (OPAAV) was significantly correlated with cardiac output/heart rate (r = 0.53; p < 0.0001) and cardiac index/heart rate (r = 0.43; p < 0.0001). In experiment 2, R-R ratio was significantly correlated with ocular pulse amplitude ratio (r = 0.85; p < 0.001). CONCLUSIONS These results show that ocular pulse amplitude, a physiological measurement obtained from the globe, is correlated with cardiac output. They imply that ocular pulse amplitude may provide a clinically useful estimate of at least the pulsatile component of ocular blood flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The impact of cardiac index on cerebral hemodynamics.

BACKGROUND AND PURPOSE Current noninvasive testing allows accurate assessment of cerebrovascular hemodynamics. The cardiovascular influence on the noninvasive assessment of cerebrovascular studies has not been defined. This study was designed to determine the effect of cardiac index (CI) on cerebral blood flow velocities, ocular pulse amplitude, ophthalmic systolic pressure, and ocular blood fl...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Ocular pneumoplethysmography and ophthalmodynamometry in the diagnosis of central retinal artery occlusion.

Ocular pneumoplethysmography and ophthalmodynamometry measure ophthalmic arterial system pressures to assess noninvasively the hemodynamics of the carotid system. A previously unreported circumstance in which these tests complement one another is central retinal artery occlusion. Typically, the ipsilateral retinal artery pressure, measured by ophthalmodynamometry, is greatly decreased or is zer...

متن کامل

Efficient Delay Characterization Method to Obtain the Output Waveform of Logic Gates Considering Glitches

Accurate delay calculation of circuit gates is very important in timing analysis of digital circuits. Waveform shapes on the input ports of logic gates should be considered, in the characterization phase of delay calculation, to obtain accurate gate delay values. Glitches and their temporal effect on circuit gate delays should be taken into account for this purpose. However, the explosive numbe...

متن کامل

A Robust SAR NLFM Waveform Selection Based on the Total Quality Assessment Techniques

Design, simulation and optimal selection of cosine-linear frequency modulation waveform (CNLFM) based on correlated ambiguity function (AF) method for the purpose of Synthetic Aperture Radar (SAR) is done in this article. The selected optimum CNLFM waveform in contribution with other waveforms are applied directly into a SAR image formation algorithm (IFA) and their quality effects performance ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 1993