Frost Formation on Fan-Supplied Tube-Fin Evaporators: A Visual and Numerical Analysis

نویسندگان

  • Diogo Londero
  • Da Silva
  • DA SILVA
چکیده

This paper presents an experimental and numerical study to evaluate the thermal-hydraulic performance of light commercial capacity evaporators operating under frosting conditions. A tube-fin heat exchanger was tested on a closed-loop wind-tunnel considering the fan performance. A visual analysis of the frost formation processes was carried out to compare the frost layer morphology in different conditions. A mathematical model was developed and the numerical results were compared with the experimental accumulated mass of frost, air flow rate and cooling capacity, with all the predictions falling within the experimental band of uncertainties. Based on this comparison, a frost density correlation was proposed for a typical range of light commercial refrigeration applications. The results show evaporator cooling capacity reductions up to 40% due to frost formation process. Moreover, the effects of air flow reduction and low conductivity frost layer on the overall thermal resistance were analyzed, when it was found that the former is the main cause of the cooling capacity reduction under frosting conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat and Mass Transfer Coefficients Under Frost Conditions In A Finned-Tube Evaporator

The objectives of this study are to provide experimental data and a correlation that can be used in the optimal design of an evaporator under frost conditions. In the present study, we tested both a single stage and a two-stage evaporator with a variation of operating parameters and fin geometry under frost conditions. The effects of tube space and fin alignment on the heat transfer performance...

متن کامل

A Study of the Air-Side Heat Transfer and Pressure Drop Characteristics of Tube-Fin â•ŸNo-Frostâ•Ž Evaporators

A study is presented on the influence of air flow rate and surface geometry on the thermal-hydraulic performance of commercial tube-fin ‘no-frost’ evaporators. A specially constructed wind-tunnel calorimeter was used in the experiments from which data on the overall thermal conductance, pressure drop, Colburn j-factor and Darcy friction factor, f, were extracted. Eight different evaporator samp...

متن کامل

Extended Correlations for Staggered Round Tube Plain Fin Heat Exchangers

This paper develops a semi-empirical expression for heat transfer in round tube plain fin heat exchangers that have relatively large fin pitch. Empirical heat transfer correlations currently available in the public domain are necessarily limited in their range of applicability, and their functional forms are generally not designed to converge to well-known physical results, for example when par...

متن کامل

Comparison Of Energy Consumption Of Ventilated And Natural Convection Evaporators Of Refrigerators And Freezers

Forced convection on heat exchangers yields to higher heat exchange coefficient and so permits to limit the temperature difference between air and the evaporator. Higher energy performances of the refrigerating cycle is affordable compared to natural convection evaporators. In Europe, many refrigerators and freezers integrate natural convection heat exchangers. Making a review of the actual ene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014