Laboratory Study of the Lightning Attractive Width for Transmission Lines

نویسندگان

  • Thongchai Disyadej
  • Stanislaw Grzybowski
چکیده

This research focuses on an investigation of the attractive width of high voltage transmission lines to lightning strokes. In order to design the optimal lightning protection, the estimated number of lightning flashes to the line, which is based on its attractive width, needs to be determined. The investigation was performed using experiments with tested models at the Mississippi State University High Voltage Laboratory. For laboratory experiments, a total of 1,900 negative and positive switching impulse voltages were applied to a conducting rod, which represented a lightning downward leader. Different tested models of transmission lines on a scale of 1:100 were used. The effect of overhead ground wires, phase conductors, and the magnitude and polarity of lightning strokes were studied. The attractive width increased gradually with the height of overhead ground wires as well as the magnitude of the lightning stroke current. Impulse polarity had an impact on the attractive width and the attractive width for negative polarity was larger than that for positive polarity. The experimental results satisfactorily coincide with other published works, based on different methods and also with the actual transmission line observations. The new expressions of the attractive width of transmission lines, based on the experimental results, were established. The accurate estimation of the attractive width can help electric power utilities plan transmission systems reliably and economically. The detailed description of the background problem, methodology, experimental results, and analysis were presented in this paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA

In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...

متن کامل

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....

متن کامل

Application of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes

In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...

متن کامل

Lightning Performance of High Voltage Transmission Lines Protected by Surge Arresters: a Simulation for the Hellenic Transmission Network

Lightning strikes to overhead transmission lines are a usual reason for unscheduled supply interruptions in the modern power systems. In an effort to maintain failure rates in a low level, providing high power quality and avoiding damages and disturbances, plenty of lightning performance estimation studies have been conducted and several design methodologies have been proposed. The protection o...

متن کامل

Return on Investment in Transmission Network Expansion Planning Considering Wind Generation Uncertainties Applying Non-dominated Sorting Genetic Algorithm

Although significant private investment is absorbed in different sectors of power systems, transmission sector is still suffering from appropriate private investment. This is because of the pricing policies of transmission services, tariffs, and especially for investment risks. Investment risks are due to the uncertain behaviour of power systems that discourage investors to invest in the transm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012