Irreversible Biamperometry Determination Of Penicillamine Based On A Flow-Injection Analysis
نویسنده
چکیده
An original flow-injection coupling irreversible biamperometric method is developed for the direct determination of penicillamine. The method depends on electrocatalytic oxidation of penicillamine at a gold electrode and the reduction of permanganate at a platinum electrode to form an irreversible biamperometric detection system. Under the applied potential difference of 0 V, in the 0.05mol/L sulfuric acid, penicillamine can be determined over the range 6.00×10-5-1.00×10-3 mol L-1with a sampling frequency of 80 samples per hour. The detection limit for penicillamine is 8.0×10-6 mol L-1 and the RSD for 19 replicate determinations of 4.0× 10-4 mol/L penicillamine is 2.89%. The proposed method was applied to the analysis of penicillamine in penicillamine tablets with satisfactory results. 2007 Trade Science Inc. INDIA Web Publication Date : 15th April, 2007 Trade Science Inc. ACAIJ, 5(1-6), 2007 [57-62] Full Paper An Indian Journal Volume 5 Issue 1-6 April 2007 Analytical CHEMISTRY l ti l
منابع مشابه
Ultra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis
Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...
متن کاملFlow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine
A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...
متن کاملAutomated Determination of Pharmaceutically and Biologically Active Thiols by Sequential Injection Analysis: A Review
The present review article presents and discusses automated sequential injection (SI) based methods for the determination of pharmaceutically and biologically important thiols, namely cysteine, N-acetylcysteine, penicillamine, glutathione and captopril. The review intends to cover a range of ten years of published research on this topic (2000 – 2009). The methods are classified according to the...
متن کاملFlow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue
Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...
متن کاملPre-concentration of Penicillamine using Fe3O4NPS and analysis of it in drug formulations through spectroscopic method
First, an effective pre-concentration of penicillamine was done via Fe3O4NPS. Then, a simple, rapid and sensitive spectrophotometric method is described for the determination of penicillamine by 2, 6-dichlorophenolindophenol (2, 6-DCPIP), as the chromogenic agent in bulk drug and formulations. It produces a bluish green coloured compound with maximum absorbance 610 nm. Bee...
متن کامل