Case Study on the Impact of Horizontal Boundary Elements Design on Seismic Behavior of Steel Plate Shear Walls

نویسنده

  • Ronny Purba
چکیده

Acase studywas conducted to investigate the seismic behavior of steel plate shear walls having boundary elements designed by two different philosophies. The first design approach does not guarantee that formation of in-span plastic hinges on horizontal boundary elements (HBEs) will be prevented, whereas the second approach guarantees that plastic hinges can only occur at the ends of HBEs. Pushover and nonlinear time-history analyses were conducted to investigate behavior. Results show that the development of in-span plastic hinges has significant consequences on the behavior of the structure through inducing (1) significant accumulation of plastic incremental deformations on the HBEs; (2) partial yielding of the infill plates; (3) lower global plastic strength compared with values predicted by code equations; and (4) total (elastic and plastic) HBE rotations greater than 0.03 radians after the structure was pushed cyclically up to a maximum lateral drift of 3%. Nonlinear time-history analyses also demonstrated that increasing the severity of the ground excitations [i.e., from design basis earthquake (DBE) to maximum considered earthquake (MCE)] acting on the structure with in-span plastic hinge accentuated the accumulation of plastic incremental deformations on the HBEs. DOI: 10.1061/(ASCE)ST.1943-541X.0000490. © 2012 American Society of Civil Engineers. CE Database subject headings: Plastic hinges; Seismic effects; Steel plates; Shear walls; Deformation; Case studies. Author keywords: In-span plastic hinge; Seismic behavior; Steel plate shear walls; Boundary elements design; Cumulative plastic incremental deformation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corner Crack Effect on the Seismic Behavior of Steel Plate Shear Wall System

Although, experimental studies have reported fracture at the corner of Steel Plate Shear Walls (SPSW), no study has been performed to investigate the crack effect, yet. Therefore, in this paper, the effect of crack at the corner of SPSWs on the seismic behavior of the system was investigated. Two probable cracks, that have been studies at the corner of SPSWs utilizing extended Finite Element me...

متن کامل

Capacity Design of Intermediate Horizontal Boundary Elements of Steel Plate Shear Walls

Consistent with capacity design principles and requirements of ductile behavior, the 2005 AISC and 2001 CSA seismic design codes require that the intermediate horizontal boundary elements HBEs of steel plate shear walls SPSWs be designed to remain essentially elastic with the exception of plastic hinges at their ends when the infill plates fully yield under seismic loading. However, the unexpec...

متن کامل

Seismic design of boundary frame members of steel plate shear walls

Steel Plate Shear Walls (SPSWs), which consist of infill steel panels surrounded by columns, called Vertical Boundary Elements (VBEs), and beams, called Horizontal Boundary Elements (HBEs), are rapidly becoming an appealing alternative lateral force resisting system for building structures in the United States, Canada, Mexico, Japan, Taiwan and other countries. This paper presents results of so...

متن کامل

Capacity Design of Vertical Boundary Elements in Steel Plate Shear Walls

Design requirements now appear in the 2005 AISC Seismic Provisions for Structural Steel Buildings (AISC, 2005b), referred to herein as The Provisions, for steel plate shear walls (SPSWs) that are designed such that their web plates buckle in shear and develop diagonal tension fi eld action when resisting lateral loads. Energy dissipation and ductility during seismic events is principally achiev...

متن کامل

Impact of High Strength Rebars on Seismic Behavior of Lightly Reinforced Boundary Elements

Considering economical reasons and attempting to reduce carbon foot print of concrete structures, there is increasing tendency toward use of high strength reinforcement in seismically active regions. ACI 318-19, Iranian steel rebars standard INSO 3132 and next edition of Iranian national building allow the use of high strength rebars in elements of ductile force resisting systems. Therefore it ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012