A model-independent method for the determination of Breit-Wigner resonance parameters is presented. The method is based on eliminating the dependence on the choice of channel basis by analyzing the trace of the K and T matrices in the coupled-channel formalism, rather than individual matrix elements of the multichannel scattering matrix.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model-independent resonance parameter extraction from the trace of K and T matrices

A model-independent method for the determination of resonance parameters as K-matrix pole parameters from a T matrix is presented. The method is based on eliminating the dependence on the choice of channel basis by analyzing the trace of the K and T matrices in the coupledchannel formalism, rather than individual matrix elements of the multichannel scattering matrix. © 2007 Elsevier B.V. PACS: ...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Sepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114

2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...

متن کامل

Ultra-Trace Determination of Silver in Water, Soil and Radiology Film Samples Using Dispersive Liquid-Liquid Microextraction and Microvolume UV–Vis Spectrophotometry

In this research, a Dispersive Liquid-Liquid MicroExtraction (DLLME) method coupled to UV-vis spectrophotometry was developed for the indirect determination of silver ion. The method is based on the catalytic effect of the silver ion on the oxidation of congo red by potassium peroxodisulphate and extraction with DLLME procedure using chloroform (extraction solvent) containing cetyltrimethyl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006