L5 – S1 Segmental Kinematics After Facet Arthroplasty

نویسندگان

  • Leonard I. Voronov
  • Robert M. Havey
  • David M. Rosler
  • Simon G. Sjovold
  • Susan L. Rogers
  • Gerard Carandang
  • Jorge A. Ochoa
  • Hansen Yuan
  • Scott Webb
  • Avinash G. Patwardhan
چکیده

BACKGROUND Facet arthroplasty is a motion restoring procedure. It is normally suggested as an alternative to rigid fixation after destabilizing decompression procedures in the posterior lumbar spine. While previous studies have reported successful results in reproducing normal spine kinematics after facet replacement at L4-5 and L3-4, there are no data on the viability of facet replacement at the lumbosacral joint. The anatomy of posterior elements and the resulting kinematics at L5-S1 are distinctly different from those at superior levels, making the task of facet replacement at the lumbosacral level challenging. This study evaluated the kinematics of facet replacement at L5-S1. METHODS Six human cadaveric lumbar spines (L1-S1, 46.7 ± 13.0 years) were tested in the following sequence: (1) intact (L1-S1), (2) complete laminectomy and bilateral facetectomy at L5-S1, and (3) implantation of TFAS-LS (Lumbosacral Total Facet Arthroplasty System, Archus Orthopedics, Redmond, Washington) at L5-S1 using pedicle screws. Specimens were tested in flexion (8Nm), extension (6Nm), lateral bending (LB, ± 6Nm), and axial rotation (AR, ± 5Nm). The level of significance was α = .017 after Bonferroni correction for three comparisons: (1) intact vs. destabilized, (2) destabilized vs. reconstructed, and (3) intact vs. reconstructed. RESULTS Laminectomy-facetectomy at L5-S1 increased the L5-S1 angular range of motion (ROM) in all directions. Flexion-extension (F-E) ROM increased from 15.3 ± 2.9 to 18.7 ± 3.5 degrees (P < .017), LB from 8.2 ± 1.8 to 9.3 ± 1.6 degrees (P < .017), and AR from 3.7 ± 2.0 to 5.9 ± 1.8 degrees (P < .017). The facet arthroplasty system decreased ROM compared to the laminectomy-facetectomy condition in all tested directions (P < .017). The facet arthroplasty system restored the L5-S1 ROM to its intact levels in LB and AR (P > .017). F-E ROM after the facet arthroplasty system implantation was smaller than the intact value (10.1 ± 2.2 vs. 15.3 ± 2.9 degrees, P < .017). The load-displacement curves after the facet arthroplasty system implantation at L5-S1 were sigmoidal, and quality of motion measures were similar to intact, demonstrating graded resistance to angular motion in F-E, LB and AR. CONCLUSIONS The facet arthroplasty system was able to restore stability to the lumbosacral segment after complete laminectomy and bilateral facetectomy, while also allowing near-normal kinematics in all planes. While F-E ROM after the facet arthroplasty system implantation was smaller than the intact value, it was within the physiologic norms for L5-S1. These results are consistent with previous studies of facet arthroplasty at L3-L4 and L4-L5 and demonstrate that TFAS technology can be adapted to the lumbosacral joint with functionality comparable to its application in superior lumbar levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior Dynamic Stabilization as a Salvage Procedure for Lumbar Facet Degeneration Following Total Disc Arthroplasty: Case report

Following an L5-S1 SB Charité disc III implantation, a 37-year-old female patient developed intractable radicular pain in the left L5 distribution. The patient underwent a minimally invasive foraminotomy, and her symptoms improved significantly. However, following recurrence of radicular pain, she showed signs of an L5-S1 facet degeneration and recurrent nerve root compression from hypertrophie...

متن کامل

Biomechanical Changes in Disc Pressure and Facet Strain after Lumbar Spinal Arthroplasty with CharitéTM in the Human Cadaveric Spine under Physiologic Compressive Follower Preload.

AIM Arthroplasty maintains the biomechanical features of a healthy disc, decreases the adjacent segment disease rate, and decreases the accelerated degeneration rate of the neighboring discs in traditional fusion procedures. However, there are only a few reports on adjacent disc pressure (DP) and facet strain (FS) after lumbar arthroplasty under a physiologic compressive preload. MATERIAL AND...

متن کامل

Relationship of Facet Tropism with Degeneration and Stability of Functional Spinal Unit

PURPOSE The authors investigated the effect of lumbar facet tropism (FT) on intervertebral disc degeneration (DD), facet joint degeneration (FJD), and segmental translational motion. MATERIALS AND METHODS Using kinetic MRI (KMRI), lumbar FT, which was defined as a difference in symmetry of more than 7 degrees between the orientations of the facet joints, was investigated in 900 functional spi...

متن کامل

Effect of Device Rigidity and Physiological Loading on Spinal Kinematics after Dynamic Stabilization : An In-Vitro Biomechanical Study.

OBJECTIVE To investigate the effects of posterior implant rigidity on spinal kinematics at adjacent levels by utilizing a cadaveric spine model with simulated physiological loading. METHODS Five human lumbar spinal specimens (L3 to S1) were obtained and checked for abnormalities. The fresh specimens were stripped of muscle tissue, with care taken to preserve the spinal ligaments and facet joi...

متن کامل

Adjacent segmental degeneration following Wallis interspinous stabilization implantation

Adjacent segmental degeneration (ASD) is a major issue after pedicular fixation. This study examined the degeneration of the adjacent levels due to the insertion of the Wallis interspinous stabilization system compared with discectomy, using magnetic resonance imaging (MRI).Thirty-eight patients diagnosed with lumbar degeneration disorders at L4-L5 were reviewed: 19 patients underwent discectom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009