US FDA clinical trial of the Tetraflex potentially accommodating IOL: comparison to concurrent age-matched monofocal controls.

نویسندگان

  • Donald R Sanders
  • Monica L Sanders
چکیده

PURPOSE To assess the efficacy of the Tetraflex (Lenstec Inc) intraocular lens (IOL) to provide enhanced near reading ability and spectacle independence relative to a monofocal control IOL in bilaterally implanted eyes tested binocularly. METHODS A prospective, age-matched, non-randomized US Food and Drug Administration clinical trial of 255 Tetraflex and 101 monofocal IOL control patients was performed. To date, 239 Tetraflex and 96 control patients were examined at 12 months postoperatively. RESULTS At 12 months postoperative, the Tetraflex patients read better than the controls at print sizes of 20/80 (P=.04), 20/63 (P=.01), 20/50 (P<.001), 20/40 (P=.001), 20/32 (P<.001), and 20/25 (P=.001). The proportion of patients reading at a speed of ≥80 words per minute was significantly higher with the Tetraflex IOL (P=.003). Ninety-six percent of Tetraflex patients reported never wearing glasses for distance compared with 80% of control patients (P<.001). Seventy-five percent of the Tetraflex patients reported near spectacle wear either never or only occasionally for small print and/or dim light (21% never) compared with 46% of control patients (P<.001) (9% never). Near add power requirement for corrected near visual acuity was less in the Tetraflex group (P<.001); 28% of Tetraflex patients required ≤1.25 diopters of near add, compared to only 7% of control patients. Spectacle independence, as measured by the proportion of patients with uncorrected distance visual acuity of 20/25 or better and various degrees of uncorrected near visual acuity, was also significantly better (P<.001) as was distance-corrected near visual acuity (P<.001). CONCLUSIONS The results support the efficacy of the Tetraflex IOL to provide enhanced near reading ability and spectacle independence relative to a monofocal IOL control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near Visual Performance Results of the Accommodating Intraocular Lens (Tetraflex)® in Comparison to Monofocal Foldable Intraocular Lens

Purpose: To evaluate the near visual performance of an accommodative intraocular lens (IOL); Tetraflex, in comparison to a standard monofocal foldable IOL in cataract surgery. Setting: Eye Research Center, Farabi Eye Hospital, Department of Ophthalmology, Tehran University of Medical Sciences, Iran. Methods: Forty six eyes of 23 patients with cataract underwent phacoemulsification and accommoda...

متن کامل

Functional reading acuity and performance: Comparison of 2 accommodating intraocular lenses.

PURPOSE To compare functional reading acuity and speed with 2 models of accommodating intraocular lenses (IOLs). SETTING Four of 12 investigative sites in a U.S. Food and Drug Administration (FDA) clinical study. METHODS In this observational study, which was part of an ongoing FDA clinical trial, the MNRead functional reading test was used to compare the reading performance of patients wit...

متن کامل

Mechanism of action of the tetraflex accommodative intraocular lens.

PURPOSE To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, a...

متن کامل

Visual and Refractive Outcomes of Phacoemulsification with Implantation of Accommodating versus Standard Monofocal Intraocular Lenses.

PURPOSE To compare distant and near visual function after cataract surgery with implantation of Crystalens HD or Tek-Clear as accommodating intraocular lenses (IOLs), versus SA60AT as a standard IOL. METHODS The study included 62 eyes of 58 patients divided into three groups using three different IOLs: Crystalens HD (Bausch and Lomb, NY, USA), Tek-Clear (Tekia, CA, USA) and SA60AT (Alcon, TX,...

متن کامل

Comparison between OPD-Scan results and visual outcomes of monofocal and multifocal intraocular lenses.

PURPOSE To compare the visual outcome, contrast sensitivity and wavefront analysis of patients that underwent cataract surgery and implantation of AcrySof SN60D3 multifocal intraocular lens with those who received the AcrySof SN60AT monofocal IOL. METHODS This was a prospective clinical trial of forty eyes that received the multifocal IOL and thirty-two eyes that received the monofocal IOL af...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 26 10  شماره 

صفحات  -

تاریخ انتشار 2010