Comparison of standardized uptake values obtained from two- and three-dimensional modes of fluorine-18 fluorodeoxyglucose PET-CT in oncological cases.
نویسندگان
چکیده
PURPOSE We investigated the usability of standardized uptake values (SUV) obtained from both two- and three-dimensional (2D and 3D) positron-emission tomography and computed tomography (PET-CT) imaging, and compared the images obtained from these techniques in terms of image quality, lesion detectability, and the presence of artifacts. MATERIALS AND METHODS Image data from 100 patients, who had undergone two PET imagings obtained in 2D and 3D mode after a low dose CT, were evaluated prospectively. Subjective analysis of 2D and 3D images was performed by two readers evaluating the following criteria: overall image quality, detectability of each identified lesion, and the presence of artifacts. The lesions recognized by the readers were also analyzed quantitatively by measuring SUV values. RESULTS There was a significant difference between the SUVs obtained in 2D and 3D modes. Regardless if the first scan was performed in 2D or 3D mode, the values obtained from 3D imaging were significantly lower than those obtained from 2D imaging (mean SUV(max) was 10.48±7.57 for 2D, and 9.66±6.93 for 3D, P < 0.001). Visual analysis did not reveal significant differences regarding lesion detectability between two modes. CONCLUSION In oncological PET-CT applications, SUV values are significantly lower in 3D compared with 2D mode. Thus when serial scanning is needed to evaluate response to therapy in the same patient, the imaging modality should be taken into account and performed with the same method to avoid misinterpretation. Additionally, 3D PET-CT imaging can be used instead of 2D PET-CT due to its shorter scanning time without loss of lesion detectability.
منابع مشابه
Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...
متن کامل18F-FDG PET/CT of advanced gastric carcinoma and association of HER2 expression with standardized uptake value
Objective(s): Expression of HER2 in gastric carcinoma has direct prognostic and therapeutic implications in patient management. The aim of this study is to determine whether a relationship exists between standardized uptake value (SUV) and expression of HER2 in advanced gastric carcinoma. Methods: We analyzed the 18F-FDG PET/CT results of 109 patients that underwent gastrectomy for advanced gas...
متن کاملThe Applications of Corrected Standardized Uptake Values in the Diagnosis of Peripheral Lung Lesions
Fluorine 18-fluorodeoxyglucose positron emission tomography/computed tomography (F-FDG PET/CT) imaging has been widely used to diagnose many types of tumors. However, many factors can affect the accuracy of standardized uptake values (SUVs). In this study, we aimed to explore the applications of corrected SUVs in the diagnosis of peripheral solitary pulmonary lesions.A retrospective study was u...
متن کاملHigh 18F-Fluorodeoxyglucose Uptake in Adrenal Angiomyolipoma
Adrenal angiomyolipoma is an extremely rare tumor, although computed tomography (CT) or magnetic resonance imaging findings of adrenal angiomyolipoma have been reported, there are no reports regarding integrated fluorine-18-fluorodeoxyglucose positron emission tomography and computed tomography ((18)F-FDG PET/CT) imaging. We report a case of adrenal angiomyolipoma showing a significantly high u...
متن کاملClinical Significance of Fluorine-18-fluorodeoxyglucose Positron Emission Tomography/computed Tomography in the Follow-up of Colorectal Cancer: Searching off Approaches Increasing Specificity for Detection of Recurrence
Background Nearly 40% of colorectal cancer (CRC) recurs within 2 years after resection of primary tumor. Imaging with fluorine-18-fluorodeoxyglucose (l8F-FDG) positron emission tomography/computed tomography (PET/CT) is the most recent modality and often applied for the evaluation of metastatic spread during the follow-up period. Our goal was to study the diagnostic importance of 18F-FDG-PET/CT...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diagnostic and interventional radiology
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2013