A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation

نویسندگان

  • S Raymond Golish
  • Jason A Oliviero
  • Eric I Francke
  • Mark D Miller
چکیده

BACKGROUND Non-operative management of midshaft clavicle fractures is standard; however, surgical management is increasing. The purpose of this study is to compare the biomechanical performance of plate versus intramedullary fixation in cyclic bending for matched pairs of cadaveric clavicles. We hypothesized that the biomechanical properties are similar. METHODS Eight sets of matched clavicles with vertical, midshaft osteotomies were prepared from fresh, frozen cadavers. A 3.5 mm dynamic compression plate or a 3.8 or 4.5 mm intramedullary device were used for fixation. Clavicles were loaded in a four-point bend at 6 different loads for 3000 cycles at 1 Hz starting with 180 N and increasing by 180 N with sampling at 2 Hz. Failure was defined as 10 mm of displacement or catastrophic construct failure prior to 10 mm of displacement. RESULTS Between constructs, there was a significant difference with large effect size in displacement at fixed loads of 180 N (P = 0.001; Cohen's d = 1.85), 360 N (P = 0.033; Cohen's d = 1.39), 540 N (P = 0.003; Cohen's d = 0.73) and 720 N (P = 0.018; Cohen's d = 0.72). There was a significant difference with large effect size in load at fixed displacements of 5 mm (P = 0.001; Cohen's d = 1.49), 7.5 mm (P = 0.011; Cohen's d = 1.06), and 10 mm (P = 0.026; Cohen's d = 0.84). CONCLUSION Plate constructs are superior in showing less displacement at fixed loads and greater loads at fixed displacements over a broad range of loads and displacements with cyclic four-point bending. The clinical relevance is that plate fixation may provide a stronger construct for early rehabilitation protocols that focus on repetitive movements in the early pre-operative period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plate Versus Intramedullary Fixation Care of Displaced Midshaft Clavicular Fractures

In recent decades, there has been a growing trend to the operative treatment of displaced midshaft clavicular fractures. Open reduction and internal plate fixation, and intramedullary nailing fixation are 2 of the widely used techniques for operative treatment, but the optimal fixation method for these types of fractures remains a topic of debate. The objective of this study was to determine th...

متن کامل

Intramedullary devices fixation versus plate fixation for adult displaced mid-shaft clavicle fractures: an update meta-analysis

Nowadays, the exact efficacy of intramedullary devices fixation and plate fixation for adult displaced midshaft clavicle fractures (DMCF) is still debated. This study aims to re-assess the functional outcomes and complications of the two optimal surgical approaches. Cochrane Central Register of Controlled Trials, EMABASE, and PubMed databases were searched for the literature that studied the ef...

متن کامل

Operative Cost Comparison: Plating Versus Intramedullary Fixation for Clavicle Fractures.

Although clavicle fractures often heal well with nonoperative management, current literature has shown improved outcomes with operative intervention for specific fracture patterns in specific patient types. The 2 most common methods of midshaft clavicle fracture fixation are intramedullary and plate devices. Through retrospective analysis, this study performed a direct cost comparison of these ...

متن کامل

Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study

BACKGROUND The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. METHODS Finite element models of the intact clavicle and of midshaft ...

متن کامل

Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.

Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Orthopaedic Surgery and Research

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2008