Zurich cementless total hip replacement: retrospective evaluation of 2nd generation implants in 60 dogs.

نویسندگان

  • Tomás G Guerrero
  • Pierre M Montavon
چکیده

OBJECTIVE To evaluate the results of application, and identify complications, of the 2nd generation of Zurich Cementless Total Hip Replacement (ZCTHR). STUDY DESIGN Case series. ANIMALS Client-owned dogs (n=60) that had ZCTHR (n=65). METHODS Dogs with ZCTHR (2001-2003) with a minimum follow-up > or =6 months were evaluated. Data included signalment, cup position, longest follow-up, complications, management of complications and outcome. RESULTS Mean follow-up was 22.68 months. Eleven cases (17%) had postoperative complications: femoral fracture (n=1; 1.5%), prosthesis luxation (7; 11%), cup loosening (2; 3%), and implant failure (1; 1.5%); 9 cases were successfully revised. Explantation of implants was performed in 1 case because of infection, and 1 dog was euthanatized after reluxation. CONCLUSIONS ZCTHR can restore function in dogs affected by disabling diseases of the coxofemoral joint. The press-fit fixation of the cup allowed for corrections in cases of incorrect positioning. Cases with aseptic loosening were revised successfully by impacting larger cups. Newer stems of this generation are shot peening treated to increase their resistance to breakage. In our cases, infection is a disastrous event, leading to implant removal. After resolution of complications, a successful final outcome was achieved in 97% of THR. CLINICAL RELEVANCE ZCTHR offers a reliable alternative for treating dogs with disabling diseases of the hip joints.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kyon Cementless Total Hip Arthroplasty

My interest in cementless Total Hip Arthroplasty began in 1993 when I was introduced to the experimental PCA-Howmedica system while visiting Dave De Young at NCSU Veterinary College. After previous experience with cemented prostheses, I was looking for a commercially available cementless system to eliminate the complications I had encountered with cemented hips, mainly aseptic implant loosening...

متن کامل

[Total hip replacement in patients with ankylosing spondylitis.].

The authors present their experience with total hip replacement in patients with ankylosing spondylitis. In the period of 1985-1997 they performed in total 66 total hip replacements in 41 patients. Of the total number of the used implants 24 were fully cemented (the average follow-up - 13 years), 3 were hybrid and 39 cementless (the average follow-up - 6 years). The results of total hip replace...

متن کامل

Robotic Total Hip Replacement Surgery in Dogs

Approximately half of the over 120,000 total hip replacement operations performed annually in the United States use cementless implants. The standard method for preparing the femoral cavity for such implants uses a mallet-driven hand-held broach whose shape matches that of (he desired implant. In-vitro experiments have supported the possibility (ha( a more accurate (and, we expect, more efficac...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Revision of an unstable HELICA endoprosthesis with a Zurich cementless total hip replacement.

A six-year-old, female, spayed Labrador Retriever was evaluated for progressive lameness of one year duration, ending in non-weight-bearing of the right hindlimb. The dog had a history of severe coxarthrosis of both hip joints, and had a HELICA hip prosthesis implanted in the right hip 18 months before. On survey radiographs, the acetabular and femoral components appeared unstable, with a large...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Veterinary surgery : VS

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2009