The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities.

نویسندگان

  • Gerry A Croteau
  • Steven E Guffey
  • Mary Ellen Flanagan
  • Noah S Seixas
چکیده

This study assessed the effectiveness of commercially available local exhaust ventilation (LEV) systems for controlling respirable dust and crystalline silica exposures during concrete cutting and grinding activities. Work activities were performed by union-sponsored apprentices and included tuck-point grinding, surface grinding, paver block and brick cutting (masonry saw), and concrete block cutting (hand-held saw). In a randomized block design, implemented under controlled field conditions, three ventilation rates (0, 30, and 75 cfm) were tested for each tool. Each ventilation treatment was replicated three times in random order for a total of nine 15-min work sessions per study subject. With the exception of the hand-held saw, the use of LEV resulted in a significant (p < 0.05) reduction in respirable dust exposure. Mean exposure levels for the 75 cfm treatments were less than that of the 30 cfm treatments; however, differences between these two treatments were only significant for paver block cutting (p < 0.01). Although exposure reduction was significant (70-90% at the low ventilation rate and 80-95% reduction at the high ventilation rate), personal respirable dust [corrected] exposures remained very high: 1.4-2.8 x PEL (permissible exposure limit) at the low ventilation rate and 0.9-1.7 x PEL at the high ventilation rate. Exposure levels found under actual field conditions would likely be lower due to the intermittent nature of most job tasks. Despite incomplete control LEV has merit, as it would reduce the risk of workers developing disease, allow workers to use a lower level of respiratory protection, protect workers during short duration work episodes reduce exposure to nearby workers, and reduce clean-up associated dust exposures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The efficacy of local exhaust ventilation for controlling dust exposures during concrete surface grinding.

This study assessed the effectiveness of a commercially available local exhaust ventilation (LEV) system for controlling respirable dust and crystalline silica exposures during concrete grinding activities. Surface grinding was conducted at six commercial building construction sites in Seattle, WA, by cement masons. Time-integrated filter samples and direct reading respirable dust concentration...

متن کامل

Silica dust exposures during selected construction activities.

This study characterized exposure for dust-producing construction tasks. Eight common construction tasks were evaluated for quartz and respirable dust exposure by collecting 113 personal task period samples for cleanup; demolition with handheld tools; concrete cutting; concrete mixing; tuck-point grinding; surface grinding; sacking and patching concrete; and concrete floor sanding using both ti...

متن کامل

Efficiency of a tool-mounted local exhaust ventilation system for controlling dust exposure during metal grinding operations.

In general, control of metal dust from hand-held disk grinders is difficult because such respirable dust tends to disperse in every direction around the grinding wheel and cannot be captured effectively by a conventional exhaust hood. The author described the application of a custom-made tool-mounted local exhaust ventilation (LEV) system attached to a hand-held disk grinder, and by laboratory ...

متن کامل

Respirable crystalline silica dust exposure during concrete finishing (grinding) using hand-held grinders in the construction industry.

Studies reporting the findings of exposure to crystalline silica dust during concrete finishing in construction settings are scarce due to the dynamic nature of the activity and the existence of many confounding factors. This study was initiated to explore the issue. A total of 49 personal respirable dust samples were collected during concrete finishing while workers used hand-held grinders. On...

متن کامل

Dust emission and efficiency of local exhaust ventilation during cast iron grinding.

A method of determining dust emission and efficiency of its removal by means of local exhaust ventilation from machinery has been described. It complies with Standard No. EN 1093-3:1996 (European Committee for Standardization, 1996) and consists in determining air pollution concentrations in the measurement duct used for air removal from the chamber incorporating devices to be tested. The air v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AIHA journal : a journal for the science of occupational and environmental health and safety

دوره 63 4  شماره 

صفحات  -

تاریخ انتشار 2002