Cost-effectiveness evaluations concerning devices for total knee arthroplasty (TKA) have little impact on real-life management of these devices. This study explored how pharmacoeconomic models can inform the procurement of TKA devices to improve their value for money. Our study included three phases: i) literature search for data of outcome, cost, and device type in TKA; ii) development of a Markov model predicting costs, QALYs, and net monetary benefit (NMB); iii) simulation of tenders aimed at value-based device procurement. Phases 1 and 2 were managed by selecting a single study as the source of data for our analysis. In Phase 3, each TKA device was associated with its values of NMB, and the tender scores were estimated. Finally, the ranking of each device in the simulated tender was determined. We identified a study published in 2016 as our source of data. Five devices were evaluated. For these devices, QALYs were 7.3952, 7.2939, 7.4952, 7.1919, 7.2930; NMB: £142,005, £140,653, £144,184, £138,040, £140,261; tender scores: 64.53, 42.53, 100, 0, 36.15, respectively. We showed that incorporating the principles of cost-effectiveness into the tendering process is feasible for TKA devices. This can maximize the value for money for these devices.
منابع مشابه
Handling the procurement of prostheses for total hip replacement: description of an original value based approach and application to a real-life dataset reported in the UK
OBJECTIVES In most European countries, innovative medical devices are not managed according to cost-utility methods, the reason being that national agencies do not generally evaluate these products. The objective of our study was to investigate the cost-utility profile of prostheses for hip replacement and to calculate a value-based score to be used in the process of procurement and tendering f...
متن کاملIs there a future for hinged prostheses in primary total knee arthroplasty? A 20-year survivorship analysis of the Blauth prosthesis.
The Blauth prosthesis is a hinged total knee replacement. We have evaluated 422 consecutive primary total knee arthroplasties using this design in 330 patients with a maximum follow-up of 20 years (mean 6). The mean age of the patients at the time of operation was 70 years (29 to 87). Using endpoints of infection, removal because of aseptic loosening, removal for any cause, and the worst case a...
متن کاملRelationship between Femoral Intercondylar Notch Narrowing on Radiography and Anatomical and Histopathologic Integrity of Anterior Cruciate Ligament in Patients Undergoing Total Knee Replacement Surgery
Abstract Introduction: The presence of cruciate ligaments are very important for normal knee kinematics. Knee arthroplasty prostheses, in which these ligaments are maintained, have better kinematics. The aim of the present study was to investigate the association between femoral intercondylar notch narrowing in radiography and clinical and histopathologic integrity of anterior cruciate li...
متن کاملThe use of 99mTc-recombinant human annexin V imaging for differential diagnosis of aseptic loosening and low-grade infection in hip and knee prostheses.
UNLABELLED The aim of this study was to assess the pattern of annexin V uptake in hip and knee prostheses suspected of being infected. METHODS A total of 7 patients undergoing revision surgery for hip or knee prostheses were studied; 5 patients had total hip replacements, and 2 had total knee replacements. Infection was confirmed by pathology, culture results, laboratory evaluation, and clini...
متن کاملThe Effect of Insert Conformity on The Wear of Total Knee Replacements
Introduction: The demand for joint replacements in young patients is increasing, and therefore there is a need to increase the lifetime of the prostheses. To fulfil this requirement, new replacements’ designs and materials are being introduced. One of the design parameters that may affect wear of total knee replacements, and hence the predicted lifetime of such prostheses, is the insert conform...
متن کامل