Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture?

نویسندگان

  • Dong Wook Kim
  • Myung Ho Rho
  • Ki Nam Kim
چکیده

OBJECTIVE This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. MATERIALS AND METHODS A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). RESULTS The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was administered. Four patients had an equivalent pain score for both treatments. This finding was also statistically significant (p = 0.001). CONCLUSION In our study, patient pain scales were significantly lower when no local anesthesia was used prior to US-FNABs of thyroid nodules as compared to when local anesthesia was administered. Therefore, we believe that when one needle puncture is used, US-FNAB should be performed without administering local anesthesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the effectiveness of local anesthesia before thyroid fine needle biopsy considering the size of the nodule

Background: Fine needle aspiration biopsy (FNAB) is usually used to distinguish the malignant and benign nodules. Applying a biopsy needle evokes a sense of fear and pain in the patients. Although some studies refute the usefulness of local anesthesia (LA) prior to fine needle aspiration biopsy, it is still debatable. This prospective cross-sectional study intended to evaluate the effect of LA ...

متن کامل

Pain levels associated with ultrasound-guided fine-needle aspiration biopsy for neck masses.

BACKGROUND The purpose of this study was to evaluate the pain levels associated with ultrasound-guided fine-needle aspiration biopsy (FNAB) of neck masses. METHODS The pain immediately and 5 minutes after the procedure without use of local anesthesia was evaluated via 100-mm visual analog scale (VAS), 11-point numeric rating scale (NRS), and 4-category verbal rating scale (VRS) in 154 patient...

متن کامل

Combination of aspiration and non-aspiration fine needle biopsy for cytological diagnosis of thyroid nodules

Background: Good cytological sample is very important for the cytological diagnosis of thyroid nodules. The aim of this study was to evaluate the adequacy of prepared samples by the combination of aspiration and non- aspiration fine needle biopsy. Methods: In this descriptive – analytical study, sampling was done simultaneously for each patient in fine needle aspiration and non-aspiration biops...

متن کامل

Clinical Application of Ultrasound-Guided Thyroid Fine Needle Aspiration Biopsy and Thinprep Cytology Test in Diagnosis of Thyroid Disease

Purpose: To study the clinical application value of ultrasound guided thyroid fine needle aspiration biopsy and thinprep cytology testing in diagnosis of thyroid disease. Methods: A total of 78 patients with thyroid nodules were enrolled, 34 males and 44 females, aged 33-64 years old with mean age of 47.6 years. All underwent thyroid module fine needle puncture after surgery to assess cell path...

متن کامل

Senthil P et al ACCURACY OF ULTRASOUND GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN THE EVALUATION OF THYROID NODULES

Background: Thyroid nodules are a common problem which requires an accurate cytological diagnosis for proper management. An essential investigation modality is fine needle aspiration cytology (FNAC) with a sensitivity ranging between 80-90%. Recommendations vary regarding the use of ultrasound in improving the accuracy of free hand fine needle aspiration biopsy. Objective: The aim of our study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009