The use of a dual dye photometric calibration method to identify possible sample dilution from an automated multichannel liquid-handling system.

نویسندگان

  • Huijin Dong
  • Zheng Ouyang
  • Jane Liu
  • Mohammed Jemal
چکیده

A significant difference between the reported volumes delivered by a fluid-filled automated liquid-handling system with eight stainless steel fixed tips was observed when a gravimetric method and a dual dye photometric method were used to measure delivered volumes between 20 and 200 microL. A series of experiments, using the default pipetting parameters, was performed which demonstrated that the difference in the reported volume was due to a dilution effect by the system liquid of the liquid handler and did not indicate an error in the delivered volumes. This dilution effect led to a decrease in the reported volume by the dual dye method, which alerted the user to the problem of sample dilution. In contrast, the gravimetric method provided the expected volume, and therefore did not alert the user to the problem. Without optimization of pipetting parameters, the dilution issue can be significant, because the resultant change in the concentration of the compound(s) of interest in the sample could lead to an unidentified error in the sample assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improved method for the calibration of continuously recorded dye dilution curves.

ONE of the main problems in the use of continuously recorded dye dilution curves has been the calibration of the obtained curves. Methods involving measurements from the "tail" of the dilution curve are often inaccurate because in this portion of the curve the concentration of dye is low. Other methods of calibration involve determinations from a sample of blood withdrawn before or after the di...

متن کامل

Magnetic removal of acid dyes from wastewater with ionic liquid linked-nanoparticles

The acid dyes are one of the most widely used commercial dyes used in the textile industries. This work investigates the ability of magnetite nanoparticles functionalized with imidazolium based ionic liquid as an efficient sorbent for removal of the Acid Blue 113 from wastewater. Fourier Transform Infrared Spectroscopy FT-IR, X-ray diffraction XRD and Transmission Electron Microscopy TEM were u...

متن کامل

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

The Use of the Ear Oximeter for Measurement of the Cardiac Output During Walking Exercise in Human Subjects ‡

For the study of walking exercise in human subjects, an accurate method for measurement of the cardiac output is needed which can be applied repeatedly and with minimal discomfort to the subject. Continuous recording of dye-dilution curves by means of an ear oximeter has been used previously,"'9'10 for estimating the cardiac output at rest, and requires only venipuncture. However, the accuracy ...

متن کامل

Dual Space Control of a Deployable Cable Driven Robot: Wave Based Approach

Known for their lower costs and numerous applications, cable robots are an attractive research field in robotic community. However, considering the fact that they require an accurate installation procedure and calibration routine, they have not yet found their true place in real-world applications. This paper aims to propose a new controller strategy that requires no meticulous calibration and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinics in laboratory medicine

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 2007