Computed tomography of single-channel cochlear implants.
نویسندگان
چکیده
Computed tomographic (CT) examinations were performed in seven patients after cochlear implant surgery. Preimplantation CT demonstrated the petrous anatomy well and revealed an abnormality in one case. Postimplantation CT adequately assessed electrode position in all cases. Malposition of the active electrode was identified in one patient. Electrode position was correlated with postimplantation audiometric testing. A "transpetrous" projection was used to image perpendicular to the active electrode within the basal turn of the cochlea. A potential pitfall was identified where the ground electrode tip appeared to be embedded in the carotid canal cortex due to partial-volume averaging. With further experience, the clinical utility of CT in cochlear implantation patients will be better defined.
منابع مشابه
Temporal bone characterization and cochlear implant feasibility in the common marmoset (Callithrix jacchus).
The marmoset (Callithrix jacchus) is a valuable non-human primate model for studying behavioral and neural mechanisms related to vocal communication. It is also well suited for investigating neural mechanisms related to cochlear implants. The purpose of this study was to characterize marmoset temporal bone anatomy and investigate the feasibility of implanting a multi-channel intracochlear elect...
متن کاملIntra-operative monitoring during cochlear implant surgery
Submit Manuscript | http://medcraveonline.com Abbreviations: CI, Cochlear implant; OR, Operating room; EI, electrode impedance; ECAP, electrically evoked compound action potential; SOE, spread of excitation; CT, computed tomography; DSP, digital signal processing; RF, radiofrequency transmitter; PC, personal computer; IR, Intra-operative; ESRTs, Electrical stapedil reflex thresholds, ECoh G, El...
متن کاملIntra-operative monitoring during cochlear implant surgery
Submit Manuscript | http://medcraveonline.com Abbreviations: CI, Cochlear implant; OR, Operating room; EI, electrode impedance; ECAP, electrically evoked compound action potential; SOE, spread of excitation; CT, computed tomography; DSP, digital signal processing; RF, radiofrequency transmitter; PC, personal computer; IR, Intra-operative; ESRTs, Electrical stapedil reflex thresholds, ECoh G, El...
متن کاملVolume Computed Tomography for navigated procedures at the lateral skull base – proof of feasibility on phantom and human temporal bone specimens
Hypothesis: High-resolution imaging as provided by flat-panel based Volume Computed Tomography (fpVCT) could increase navigation accuracy and could therefore be valuable on lateral skull base procedures. O. Majdani S. Bartling Th. Rodt Methods: In the first part of the study we evaluated the accuracy of the image guided surgery (IGS) system using a custommade phantom that H. Eilers was scanned ...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 7 1 شماره
صفحات -
تاریخ انتشار 1986