Revised formulas for summarizing retinal vessel diameters.
نویسندگان
چکیده
Background/Purpose. Recent findings suggest that an objective assessment of retinal vessel caliber from fundus photographs provide information about the association of microvascular characteristics with macrovascular disease. Current methods used to quantify retinal vessel caliber, introduced by Parr(1,2) and Hubbard,(3) are not independent of scale and are affected by the number of vessels. To improve upon these methods we introduce revised formulas for quantifying vessel caliber. Methods. Revised formulas were estimated using retinal vessel measurements from 44 young adults free of hypertension and diabetes. Comparisons between the two methods were done using digitized photographs from 4926 participants at the baseline examination of the Beaver Dam Eye Study (BDES), an ongoing population-based cohort study initiated in 1987. Individual arterioles and venules were measured using semi-automated computer software from which summary measures were calculated. Results. Correlation coefficients between the Parr-Hubbard and revised formulas were high (Pearson correlation coefficients ranging from 0.94 to 0.98). Both arteriolar and venular caliber significantly increased with an increasing number of vessels measured using the Parr-Hubbard formulas (p < 0.001), which in turn affected the relationship to mean arterial blood pressure. To the contrary, the revised formulas were not affected by the number of measured vessels (p > 0.50). Conclusions. We describe revised formulas for summarizing retinal vessel diameters measured from fundus photographs to be used in future studies and analyses. The revised formulas correlate highly with the previously used Parr-Hubbard formulas, but offer the advantages of being more robust against variability in the number of vessels observed, being independent of image scale, and being easier to implement.
منابع مشابه
Asymmetry of retinal arteriolar branch widths at junctions affects ability of formulae to predict trunk arteriolar widths.
PURPOSE To describe a revised formula for the estimation of retinal trunk arteriole widths from their respective arteriolar branch widths that improves the summarizing of retinal arteriolar diameters. METHODS A group of young, healthy individuals underwent retinal photography and arteriolar and venular branching points were identified. Vessel widths of the vessel trunks and their branches wer...
متن کاملExtracting Vessel Centerlines From Retinal Images Using Topographical Properties and Directional Filters
In this paper we consider the problem of blood vessel segmentation in retinal images. After enhancing the retinal image we use green channel of images for segmentation as it provides better discrimination between vessels and background. We consider the negative of retinal green channel image as a topographical surface and extract ridge points on this surface. The points with this property are l...
متن کاملRetinal Vessel Diameters and Their Relationship with Cardiovascular Risk and All-Cause Mortality in the Inter99 Eye Study: A 15-Year Follow-Up
Purpose. To describe associations between retinal vessel diameters and cardiovascular risk markers and mortality. Methods. The present study included 908 persons aged 30 to 60 years. Vessel diameters were expressed as central retinal venular equivalent (CRVE) and central retinal arteriolar equivalent (CRAE). Multiple linear regression analyses and Cox regression models were used. Results. Multi...
متن کاملGenome-wide linkage study of retinal vessel diameters in the Beaver Dam Eye Study.
Retinal vessels can be observed noninvasively and provide a window to microvascular systems elsewhere in the body. Generalized retinal arteriolar narrowing can represent structural changes resulting from persistent high blood pressure. However, data from recent studies also suggest that generalized retinal arteriolar narrowing might precede hypertension and contribute to its pathogenesis. To de...
متن کاملEffects of dopamine on human retinal vessel diameter and its modulation during flicker stimulation.
We performed a randomized, subject-blinded, placebo and time-controlled, two-way crossover study in 12 healthy male subjects. Placebo or dopamine was administered on two separate study days. After saline infusion, dopamine hydrochloride was infused in three consecutive doses (5, 10, and 15 microg x kg(-1) x min(-1)). Plasma levels of dopamine were determined at each perfusion step. Arterial and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Current eye research
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2003